Suppr超能文献

带有硬塑料护套和塑料翼的穿刺针可减少超声引导下腹腔穿刺术中重复穿刺的尝试:一项回顾性病例对照研究。

Puncture needle with a hard plastic sheath and plastic wings minimizes repuncture attempts in ultrasound-guided paracentesis: a retrospective case-control study.

作者信息

Son Il Wan, Kim Suk, Hong Seung Baek, Lee Nam Kyung, Jeong Mi Ri, Han Sung Yong, Woo Hyun Young

机构信息

Department of Radiology, Dongnam Institution of Radiological & Medical Sciences, Busan, Korea.

Department of Radiology, Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.

出版信息

J Yeungnam Med Sci. 2022 Jan;39(1):18-23. doi: 10.12701/yujm.2021.01109. Epub 2021 Jul 12.

Abstract

BACKGRUOUND

This study was performed to evaluate periprocedural factors, complications, and repuncture rate of the newly developed puncture needle and compare it with the routinely used puncture needle for ultrasound (US)-guided paracentesis.

METHODS

We retrospectively identified 137 patients who underwent US-guided paracentesis between July 2018 and March 2019. Among them, 82 patients underwent US-guided paracentesis with a newly developed puncture needle. The other 55 patients underwent US-guided paracentesis with a routinely used puncture needle. The periprocedural factors, complications, and repuncture rate were compared between the two groups using the Mann-Whitney U test and Fisher exact test. The repuncture-associated factors were assessed using logistic regression analysis.

RESULTS

There were no major or minor complications in either group. The rate of repuncture was significantly lower in the group using the newly developed puncture needle compared with the group using the routinely used puncture needle (p=0.01). The duration of the procedure was significantly shorter with the newly developed puncture needle compared with the routinely used puncture needle (p=0.01). In univariate analysis, the thickness of the abdominal wall (p=0.04) and the use of the newly developed puncture needle (p=0.01) were significantly associated with the rate of repuncture. In multivariate analysis, only the use of the newly developed puncture needle was significantly associated with the rate of repuncture.

CONCLUSION

Using this novel puncture needle with a hard plastic sheath and plastic wings, the rate of repuncture and the duration of the procedure were decreased without complications of US-guided paracentesis.

摘要

背景

本研究旨在评估新开发的穿刺针的围手术期因素、并发症和再次穿刺率,并将其与常规使用的超声(US)引导下腹腔穿刺术穿刺针进行比较。

方法

我们回顾性分析了2018年7月至2019年3月期间接受US引导下腹腔穿刺术的137例患者。其中,82例患者使用新开发的穿刺针进行US引导下腹腔穿刺术。另外55例患者使用常规穿刺针进行US引导下腹腔穿刺术。使用Mann-Whitney U检验和Fisher精确检验比较两组的围手术期因素、并发症和再次穿刺率。使用逻辑回归分析评估再次穿刺相关因素。

结果

两组均未出现严重或轻微并发症。与使用常规穿刺针的组相比,使用新开发穿刺针的组再次穿刺率显著降低(p = 0.01)。与常规穿刺针相比,新开发的穿刺针手术时间显著缩短(p = 0.01)。单因素分析中,腹壁厚度(p = 0.04)和使用新开发的穿刺针(p = 0.01)与再次穿刺率显著相关。多因素分析中,只有使用新开发的穿刺针与再次穿刺率显著相关。

结论

使用这种带有硬塑料护套和塑料翼的新型穿刺针,可降低US引导下腹腔穿刺术的再次穿刺率和手术时间,且无并发症。