Suppr超能文献

Auscl-D:一种无汞数字听诊血压计。

Auscl-D: a mercury-free digital auscultatory sphygmomanometer.

机构信息

Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, India.

Dayanand Medical College & Hospital (DMCH), Ludhiana, India.

出版信息

J Med Eng Technol. 2021 Nov;45(8):656-663. doi: 10.1080/03091902.2021.1946182. Epub 2021 Jul 13.

Abstract

More than quarter of world's population is consumed by hypertension, leading to premature death of thousands of people per year across the globe. One of the major reasons behind hypertension misdiagnosis is inaccurate blood pressure (BP) measurements, which can be attributed to various human or instrumentation errors. Currently used BP measuring sphygmomanometers, suffers from poor reliability, performance deterioration over time or are unable to meet environmental protection protocols. In this article, we propose a low-cost, highly portable, light-weight, easily manufacturable, battery operated, mercury free, auscultation based digital sphygmomanometer - Auscl-D, for easy and accurate BP measurements. The proposed device can be made from easily available components with cheap manufacturing processes available throughout globe, even in remote areas. The device demonstrated to have accuracy comparable to mercury sphygmomanometer, which is the gold-standard for BP measurements. The preliminary clinical trials were conducted at Dayanand Medical College & Hospital (DMCH) (Ludhiana, India), to compare the performance of proposed device with commonly used aneroid sphygmomanometers employing the auscultatory method and validated oscillometric sphygmomanometers from MicroLife. The test results show good agreement for systolic and diastolic BP measurements taken using Auscl-D device compared to the aneroid and oscillometric types. This shows the potential of proposed design to serve as low-cost, highly portable replacement for conventionally used sphygmomanometers, without the toxicity and reliability issues.

摘要

全球超过四分之一的人口患有高血压,导致每年有数千人因此过早死亡。高血压误诊的主要原因之一是血压测量不准确,这可能归因于各种人为或仪器误差。目前使用的血压测量血压计存在可靠性差、随时间推移性能下降或无法满足环保协议等问题。在本文中,我们提出了一种低成本、高便携性、重量轻、易于制造、电池供电、无汞、基于听诊的数字血压计——Ausc1-D,用于进行简单准确的血压测量。该设备可以使用全球范围内都可以轻松获得的组件,并且使用便宜的制造工艺制造,即使在偏远地区也可以制造。该设备的准确性与汞柱血压计相当,后者是血压测量的金标准。初步临床试验在 Dayanand Medical College & Hospital (DMCH)(印度 Ludhiana)进行,旨在比较拟议设备与使用听诊法的常用无液血压计和 MicroLife 的验证示波法血压计的性能。测试结果表明,与无液和示波类型相比,使用 Auscl-D 设备测量的收缩压和舒张压具有良好的一致性。这表明,拟议的设计有可能成为传统使用的血压计的低成本、高便携性替代品,而不会出现毒性和可靠性问题。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验