Pare E M, Monforte J R, Gault R, Mirchandani H
Grand Valley State College, Allendale, Michigan 49401.
J Anal Toxicol. 1987 Nov-Dec;11(6):272-5. doi: 10.1093/jat/11.6.272.
Selected ion monitoring gas chromatography/mass spectrometry was employed to quantitate fentanyl in blood, liver, and kidney from a death attributed to a fentanyl overdose. The concentration of fentanyl was 3 ng/mL blood, 11 ng/g liver and 14 ng/g kidney.