The aim of this randomized control clinical trial was to compare the soft tissue response to mechanical root instrumentation procedures performed using periodontal curettes with different-sized working parts.
Twenty patients affected by Stage 3 Grade B periodontitis - a total of 109 teeth - were treated with either Mini-Five Gracey Curettes (MFC) or Conventional Gracey Curettes (CGC). Measurements were performed by a blinded examiner at baseline and at 6 weeks. Outcome measurements included pocket depth (PD), recession depth (RD), and difference in RD (∆RD).
The use of MFC significantly reduced soft tissue shrinkage (1.5 ± 1 vs 2.4 ± 1.3; difference: -0.9 mm; P < 0.001). Patients in the MFC (test) group experienced lower gingival recession (GR), especially in both thin (2 ± 0.4 mm vs 3.1 ± 0.5 mm; difference: -1.1; P < 0.001) and medium (1.6 ± 0.5 mm vs 2.6 ± 0.6; difference: -1 mm; P = 0.010) periodontal phenotypes. Severe periodontal pockets (PD ≥ 7 mm) of patients in the MFC group experienced significantly lower soft tissue shrinkage than those in the CGC (control) group, regardless of periodontal phenotype.
The use of MFC resulted in a greater PD reduction and lower rate of GR in the short term. Nonsurgical periodontal treatment performed with CGC led to more soft tissue shrinkage, particularly when performed in patients with a thin periodontal phenotype.
本随机对照临床试验旨在比较使用牙周刮匙不同工作部分的机械根管预备程序对软组织的反应。
20 名患有 3 期 B 级牙周炎的患者(共 109 颗牙齿)分别使用 Mini-Five Gracey 刮匙(MFC)或常规 Gracey 刮匙(CGC)进行治疗。由一名盲法检查者在基线和 6 周时进行测量。主要观察指标包括牙周袋深度(PD)、牙龈退缩深度(RD)和 RD 差值(∆RD)。
使用 MFC 可显著减少软组织退缩(1.5 ± 1 比 2.4 ± 1.3;差值:-0.9 毫米;P < 0.001)。MFC(试验)组的患者发生牙龈退缩(GR)的程度较低,尤其是在薄型(2 ± 0.4 毫米比 3.1 ± 0.5 毫米;差值:-1.1 毫米;P < 0.001)和中型(1.6 ± 0.5 毫米比 2.6 ± 0.6 毫米;差值:-1 毫米;P = 0.010)牙周表型。MFC 组中 PD ≥ 7 毫米的严重牙周袋患者的软组织退缩程度明显低于 CGC(对照)组,无论牙周表型如何。
MFC 的使用在短期内可导致 PD 更大程度的降低和 GR 发生率更低。在薄型牙周表型患者中,使用 CGC 进行非手术牙周治疗会导致更多的软组织退缩。