Transperineal ultrasound shear-wave elastography is a reliable tool for assessment of the elastic properties of the levator ani muscle in women.

机构信息

Department of Obstetrics and Gynecology, Poitiers University Hospital, 2, rue de la Miletrie, 86000, Poitiers, France.

Université de Nantes, Mouvement - Interactions - Performance, MIP, EA4334, 44000, Nantes, France.

出版信息

Sci Rep. 2021 Jul 30;11(1):15532. doi: 10.1038/s41598-021-95012-8.

Abstract

Our main objective was to assess the intraoperator intersession reproducibility of transperineal ultrasound Shear Wave Elastography (SWE) to measure the levator ani muscle (LAM) elastic properties. Secondary objective was to compare reproducibility when considering the mean of three consecutives measurements versus one. In this prospective study involving non-pregnant nulliparous women, two visits were planned, with a measurement of the shear modulus (SM) on the right LAM at rest, during Valsalva maneuver and maximal contraction. Assessments were done with a transperineal approach, using an AIXPLORER device with a linear SL 18-5 (5-18 MHz) probe. For each condition, 3 consecutive measures were performed at each visit. The mean of the three measures, then the first one, were considered for the reproducibility by calculating intraclass correlation coefficient (ICC), and coefficient of variation (CV). Twenty women were included. Reproducibility was excellent when considering the mean of the 3 measures at rest (ICC = 0.90; CV = 15.7%) and Valsalva maneuver (ICC = 0.94; CV = 10.6%), or the first of the three measures at rest (ICC = 0.87; CV = 18.6%) and Valsalva maneuver (ICC = 0.84; CV = 19.9%). Reproducibility was fair for measurement during contraction. Transperineal ultrasound SWE is a reliable tool to investigate LAM elastic properties at rest and during Valsalva maneuver.

摘要

我们的主要目标是评估经会阴超声剪切波弹性成像(SWE)在测量肛提肌(LAM)弹性特性方面的操作者内- session 可重复性。次要目标是比较考虑三次连续测量的平均值与一次测量的可重复性。在这项涉及非妊娠初产妇的前瞻性研究中,计划进行两次就诊,在静息、Valsalva 动作和最大收缩期间测量右侧 LAM 的剪切模量(SM)。评估使用经会阴方法,使用具有线性 SL 18-5(5-18 MHz)探头的 AIXPLORER 设备进行。对于每种情况,在每次就诊时进行 3 次连续测量。考虑到三次测量的平均值,然后是第一次测量,通过计算组内相关系数(ICC)和变异系数(CV)来评估可重复性。共纳入 20 名女性。当考虑静息时三次测量的平均值(ICC=0.90;CV=15.7%)和 Valsalva 动作(ICC=0.94;CV=10.6%)时,或静息时三次测量的第一次(ICC=0.87;CV=18.6%)和 Valsalva 动作(ICC=0.84;CV=19.9%)时,可重复性良好。在收缩期间的测量中,可重复性为中等。经会阴超声 SWE 是一种可靠的工具,可用于研究 LAM 在静息和 Valsalva 动作期间的弹性特性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/afe6/8324884/e029d5bba516/41598_2021_95012_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验