Hou Xiaoyi, Rokohl Alexander C, Meinke Marius M, Li Senmao, Liu Jinhua, Fan Wanlin, Lin Ming, Jia Renbing, Guo Yongwei, Heindl Ludwig M
Department of Ophthalmology, University of Cologne, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany.
Department of Ophthalmology, Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Quant Imaging Med Surg. 2021 Aug;11(8):3735-3748. doi: 10.21037/qims-20-1016.
Standardized pre-operative assessment of the lower eyelid tension is essential to determine the optimal surgical technique. However, quantitative analysis using the conventional distraction test is inaccurate and user-dependent. Our purpose was to introduce a novel, standardized three-dimensional distraction test for measuring lower eyelid tension and to determine its standard values in a Caucasian population.
In 94 participants (50 men and 44 women; age 21-85 years), a 15.9-g weighted eyelid hook was used to pull down the lower eyelid. Two three-dimensional images were acquired with a VECTRA M3 stereophotogrammetry device-one in the neutral position without a hook and the other in the distracted position with the eyelid hook. The images of all participants in both positions were measured twice by a single observer.
There was no clinical (>1 mm) or statistically significant difference between the two repeated measurements of all the inter-landmark linear distances in both positions (P≥0.05, respectively). The mean distracted displacement between the neutral and distracted position for margin reflex distance was 5.50±1.53 mm, without any age-specific difference (P=0.08); however, a significant gender-specific difference was observed as men had significantly greater displacement than women (P<0.001).
Our proposed standardized three-dimensional distraction test for assessing lower eyelid tension using an eyelid hook and a simple landmark-based system seems to provide high reliability. This novel and simple method might be helpful for the preoperative planning of eyelid surgeries.
下睑张力的标准化术前评估对于确定最佳手术技术至关重要。然而,使用传统牵拉试验进行定量分析不准确且依赖于使用者。我们的目的是引入一种新颖的、标准化的三维牵拉试验来测量下睑张力,并确定其在白种人群中的标准值。
在94名参与者(50名男性和44名女性;年龄21 - 85岁)中,使用一个15.9克重的眼睑钩向下牵拉下睑。用VECTRA M3立体摄影测量装置获取两张三维图像——一张是未使用眼睑钩的中立位图像,另一张是使用眼睑钩的牵拉位图像。所有参与者在两个位置的图像均由一名观察者测量两次。
两个位置所有地标间线性距离的两次重复测量之间,在临床(>1毫米)或统计学上均无显著差异(P分别≥0.05)。边缘反射距离在中立位和牵拉位之间的平均牵拉位移为5.50±1.53毫米,无任何年龄特异性差异(P = 0.