Suppr超能文献

可摘局部义齿的应力分布及患者满意度:有限元分析与随机试点研究。

Stress distribution and patient satisfaction in flexible and cast metal removable partial dentures: Finite element analysis and randomized pilot study.

作者信息

Kumar Niraj, Koli Dheeraj Kumar, Jain Veena, Nanda Aditi

机构信息

Department of Prosthodontics, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, 110029, India.

出版信息

J Oral Biol Craniofac Res. 2021 Oct-Dec;11(4):478-485. doi: 10.1016/j.jobcr.2021.06.004. Epub 2021 Jul 5.

Abstract

PURPOSE

To compare stress distribution in polyacetyl based flexible RPD (FRPD) with cast metal RPD (CRPD) by using three-dimensional finite element analysis (FEA) and patient satisfaction by using OHIP-14 questionnaire in participants with Kennedy's class I partially edentulous mandibular arch rehabilitated with CRPD and FRPD.

MATERIAL AND METHODS

For FEA, 3D models of Kennedy's class I partially edentulous mandibular arch, CRPD in chrome-cobolt alloy, and polyacetyl based FRPD were geometrically modelled and subjected to a vertical load of 100 ​N bilaterally. The in vivo comparison of satisfaction was assessed by enrolling 22 participants with Kennedy's class I partially edentulous mandibular arch. After randomization, 11 participants were rehabilitated by CRPD (group C), and 11 participants by polyacetyl based FRPD (group F). OHIP-14 questionnaire in Hindi language was filled at 1 week and 1 year after denture insertion.

RESULTS

Von Mises stress distribution in CRPD was maximum in mesial rest seat of the primary abutment (100 ​MPa) and minimum for edentulous ridge (7 ​MPa on bone and 6 ​MPa on mucosa). Von Mises stress distribution for polyaccetyl based FRPD was maximum in ridge (25 ​MPa) and minimum in periodontal ligament of the second premolar (3 ​MPa). Patient satisfaction in group F was significantly more than in group C at end of 1 year ( ​= ​.0158).

CONCLUSION

FRPD is useful in periodontally compromised abutment teeth and CRPD in resorbed ridge conditions. Patient satisfaction is more with polyacetyl based flexible RPD when compared with cast metal RPD at the end of 1 year.

摘要

目的

通过三维有限元分析(FEA)比较聚乙酰基柔性可摘局部义齿(FRPD)与铸造金属可摘局部义齿(CRPD)的应力分布,并使用OHIP - 14问卷评估采用CRPD和FRPD修复肯尼迪I类下颌部分牙列缺损患者的满意度。

材料与方法

对于有限元分析,对肯尼迪I类下颌部分牙列缺损、铬钴合金CRPD和聚乙酰基FRPD的三维模型进行几何建模,并在两侧施加100 N的垂直载荷。通过招募22名肯尼迪I类下颌部分牙列缺损的参与者进行满意度的体内比较。随机分组后,11名参与者采用CRPD修复(C组),11名参与者采用聚乙酰基FRPD修复(F组)。在义齿植入后1周和1年时用印地语填写OHIP - 14问卷。

结果

CRPD中的冯·米塞斯应力分布在主要基牙的近中支托处最大(100 MPa),在无牙嵴处最小(骨上7 MPa,黏膜上6 MPa)。聚乙酰基FRPD的冯·米塞斯应力分布在嵴处最大(25 MPa),在第二前磨牙的牙周膜处最小(3 MPa)。1年后F组患者的满意度显著高于C组(P = 0.0158)。

结论

FRPD适用于牙周状况不佳的基牙,CRPD适用于牙槽嵴吸收的情况。与铸造金属可摘局部义齿相比,聚乙酰基柔性可摘局部义齿在1年后患者满意度更高。

相似文献

本文引用的文献

1
Nonmetal clasp dentures: What is the evidence about their use?非金属卡环义齿:关于其使用的证据有哪些?
J Indian Prosthodont Soc. 2020 Jul-Sep;20(3):278-284. doi: 10.4103/jips.jips_459_19. Epub 2020 Jul 17.
5
Revisiting the Removable Partial Denture.重新审视可摘局部义齿
Dent Clin North Am. 2019 Apr;63(2):263-278. doi: 10.1016/j.cden.2018.11.007. Epub 2019 Jan 30.
7
Removable partial dentures: The clinical need for innovation.可摘局部义齿:临床创新的需求。
J Prosthet Dent. 2017 Sep;118(3):273-280. doi: 10.1016/j.prosdent.2017.01.008. Epub 2017 Mar 23.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验