Outflow facility was measured in human eye bank eyes following penetrating keratoplasty (PKP) and cataract extraction. After measuring baseline outflow facility, a PKP and lens extraction was performed with the corneal button replaced by both interrupted "through-and-through" sutures and a conventional mid-to-deep stromal running suture. Outflow facility was unchanged from baseline with both sutures. However, following removal of through-and-through sutures outflow facility decreased 37%. This same suturing procedure was repeated in a second group of phakic eyes in which suture depth did not influence outflow facility.
在穿透性角膜移植术(PKP)和白内障摘除术后,对人眼库的眼睛进行了流出易度测量。在测量基线流出易度后,进行了PKP和晶状体摘除术,角膜植片用间断“贯穿”缝线和传统的中深层基质连续缝线进行替换。两种缝线的流出易度均与基线相比无变化。然而,在拆除贯穿缝线后,流出易度下降了37%。在第二组有晶状体眼中重复了相同的缝合程序,其中缝线深度不影响流出易度。