Suppr超能文献

不同扫描仪类型和扫描体部位置对下颌全颌数字化种植体扫描精度的影响:一项体外研究。

Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study.

机构信息

Buser Foundation Scholar for Implant Dentistry, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.

Department of Orthodontics, Yeditepe University, Faculty of Dentistry, Istanbul, Turkey.

出版信息

J Prosthodont. 2022 Jun;31(5):419-426. doi: 10.1111/jopr.13418. Epub 2021 Sep 21.

Abstract

PURPOSE

To compare the accuracy (trueness and precision) of scans of a newly introduced intraoral scanner (IOS) (Virtuo Vivo) and a widely used IOS (Trios 3) to a laboratory scanner (LBS) (Cares 7 SERIES) for 6 implants placed in an edentulous mandible, and to investigate the effect of scan body location on trueness.

MATERIAL AND METHODS

Scanbodies were tightened on 6 implants placed in an edentulous polymethylmethacrylate mandibular model. An industrial scanner was utilized to generate a master reference model STL file. Three different scanners were used to scan the model (2 IOSs and 1 LBS), and the scans (n = 10) were exported into STL files. Best-fitting algorithm was used to superimpose test scans over the MRM-STL (nominal). ANOVA and Tukey HSD tests were performed to analyze the data (α = 0.05).

RESULTS

The distance deviations in Car7-LBS scans were the highest (p < 0.001), whereas those in Tri-IOS scans were the lowest (p < 0.001). Vir-IOS had lower angular deviations than those of Tri-IOS (p = 0.031). In Vir-IOS scans, SB5 had higher distance deviations than SB2 (p = 0.029) and SB3 (p = 0.044). In Car7-LBS scans, SB1 had higher distance deviations than SB3 (p = 0.015) and SB5 (p = 0.005). In Tri-IOS scans, SB1 had higher mean distance deviations than SB2 and SB5 (p = 0.005). Vir-IOS had lower precision than Car7-LBS (distance deviation data) (p = 0.01). No difference was found among scanners for the precision of angular deviation data (p = 0.840).

CONCLUSION

When trueness and precision were considered, distance and angular deviations depended on the scanner type. None of the scanners outperformed others in accuracy considering all distance and angular deviations. Scan body location affected only the trueness (distance deviations).

摘要

目的

比较一种新引入的口腔内扫描仪(IOS)(Virtuo Vivo)和一种广泛使用的 IOS(Trios 3)与实验室扫描仪(LBS)(Cares 7 SERIES)扫描 6 个植入物在无牙下颌模型中的准确性(准确性和精密度),并研究扫描体位置对准确性的影响。

材料和方法

将扫描体固定在无牙聚甲基丙烯酸甲酯下颌模型上的 6 个种植体上。使用工业扫描仪生成主参考模型 STL 文件。使用 3 种不同的扫描仪(2 种 IOS 和 1 种 LBS)扫描模型,将扫描(n=10)导出为 STL 文件。使用最佳拟合算法将测试扫描叠加到 MRM-STL(标称值)上。进行方差分析和 Tukey HSD 检验来分析数据(α=0.05)。

结果

Car7-LBS 扫描的距离偏差最大(p<0.001),而 Tri-IOS 扫描的距离偏差最小(p<0.001)。Vir-IOS 的角度偏差低于 Tri-IOS(p=0.031)。在 Vir-IOS 扫描中,SB5 的距离偏差高于 SB2(p=0.029)和 SB3(p=0.044)。在 Car7-LBS 扫描中,SB1 的距离偏差高于 SB3(p=0.015)和 SB5(p=0.005)。在 Tri-IOS 扫描中,SB1 的平均距离偏差高于 SB2 和 SB5(p=0.005)。Vir-IOS 的精密度低于 Car7-LBS(距离偏差数据)(p=0.01)。在角度偏差数据的精密度方面,扫描仪之间没有差异(p=0.840)。

结论

当考虑准确性时,距离和角度偏差取决于扫描仪类型。在考虑所有距离和角度偏差时,没有一种扫描仪在准确性方面优于其他扫描仪。扫描体位置仅影响准确性(距离偏差)。