Suppr超能文献

外置骨骼固定钉双向插入对犬类尸体骨轴向拔出强度的影响。

Effect of Bidirectional Insertion of External Skeletal Fixation Pins on Axial Pullout Strength in Canine Cadaveric Bone.

机构信息

Oklahoma State University, Veterinary Clinical Sciences, Stillwater, Oklahoma, United States.

Purdue University, Veterinary Clinical Sciences, West Lafayette, Indiana, United States.

出版信息

Vet Comp Orthop Traumatol. 2022 Jan;35(1):26-32. doi: 10.1055/s-0041-1735550. Epub 2021 Sep 21.

Abstract

OBJECTIVE

The aim of this study was to evaluate the effect of bidirectional insertion on axial pullout strength of tapered run out (TRO), traditional negative profile (TNP) and positive profile (PP) pins.

STUDY DESIGN

Cadaveric adult canine tibiae were harvested. Tapered run out pins (Group 1) were inserted unidirectionally to the desired position; bidirectionally past the desired position, then withdrawn to the desired position (Group 2); and bidirectionally as described for Group 2, repeated twice (Group 3). Traditional negative profile pins (Group 4-6) and PP pins (Group 9-11) were placed in the same manner. Tapered run out (Group 7), TNP (Group 8) and PP pins (Group 12) were driven unidirectionally such that the shaft of the pin violated the cis-cortex. A servohydraulic testing machine extracted the pins and measured axial peak pullout strength.

RESULTS

Positive profile pins had significantly greater pullout strength than TRO and TNP pins placed unidirectionally to the desired position. Method of insertion had no effect on peak pullout strength of TNP pins. TRO and PP pins inserted unidirectionally to the desired position had significantly greater peak pullout strengths than insertion bidirectionally or if the shaft of the pin violated the cis-cortex.

CONCLUSION

The authors recommend that pins used for external skeletal fixation should be placed unidirectionally to the desired position with fluoroscopic guidance, intra-operative depth gauge measurements or measurements from preoperative radiographs. Repositioning pins results in loss of peak pullout strength with TRO and PP pins.

摘要

目的

本研究旨在评估锥形退出(TRO)、传统负型(TNP)和正型(PP)销钉双向插入对轴向拔出强度的影响。

研究设计

采集成年犬胫骨标本。将锥形退出销钉(第 1 组)单向插入所需位置;双向插入超过所需位置,然后撤回至所需位置(第 2 组);并按第 2 组的方式重复双向插入两次(第 3 组)。以相同的方式放置传统负型销钉(第 4-6 组)和 PP 销钉(第 9-11 组)。锥形退出(第 7 组)、TNP(第 8 组)和 PP 销钉(第 12 组)单向插入,使销钉杆违反皮质内。伺服液压试验机提取销钉并测量轴向最大拔出强度。

结果

与单向插入至所需位置的 TRO 和 TNP 销钉相比,正型销钉具有显著更高的拔出强度。插入方式对 TNP 销钉的峰值拔出强度没有影响。单向插入至所需位置的 TRO 和 PP 销钉的峰值拔出强度明显大于双向插入或销钉杆违反皮质内的插入强度。

结论

作者建议,用于外部骨骼固定的销钉应在透视引导、术中深度计测量或术前 X 线片测量的指导下,单向插入至所需位置。重新定位销钉会导致 TRO 和 PP 销钉的峰值拔出强度丧失。