Suppr超能文献

超高 b 值(3000 s/mm)扩散加权磁共振成像在 3T 前列腺癌中的临床影响:与 b 值 2000 s/mm 的比较。

Clinical impact of ultra-high b-value (3000 s/mm) diffusion-weighted magnetic resonance imaging in prostate cancer at 3T: comparison with b-value of 2000 s/mm.

机构信息

Department of Radiology, Kawasaki Medical School, Kurashiki, Japan.

Philips Japan, Konan 2-13-37, Minato-ku, Tokyo, Japan.

出版信息

Br J Radiol. 2022 Mar 1;95(1131):20210465. doi: 10.1259/bjr.20210465. Epub 2021 Sep 24.

Abstract

OBJECTIVE

High b-value diffusion-weighted imaging (hDWI) with a b-value of 2000 s/mm provides insufficient image contrast between benign and malignant tissues and an overlap of apparent diffusion coefficient (ADC) between Gleason grades (GG) in prostate cancer (PC). We compared image quality, PC detectability, and discrimination ability for PC aggressiveness between ultra-high b-value DWI (uhDWI) of 3000 s/mm and hDWI.

METHODS

The subjects were 49 patients with PC who underwent 3T multiparametric MRI. Single-shot echo-planar DWI was acquired with b-values of 0, 2000, and 3000 s/mm. Anatomical distortion of prostate (AD), signal intensity of benign prostate (PSI), and lesion conspicuity score (LCS) were assessed using a 4-point scale; and signal-to-noise ratio, contrast-to-noise ratio, and mean ADC (×10 mm/s) of lesion (lADC) and surrounding benign region (bADC) were measured.

RESULTS

PSI was significantly lower in uhDWI than in hDWI ( < 0.001). AD, LCS, signal-to-noise ratio, and contrast-to-noise ratio were comparable between uhDWI and hDWI (all > 0.05). In contrast, lADC was significantly lower than bADC in both uhDWI and hDWI (both < 0.001). In comparison of lADC between tumors of ≤GG2 and those of ≥GG3, both uhDWI and hDWI showed significant difference ( = 0.007 and = 0.021, respectively). AUC for separating tumors of ≤GG2 from those of ≥GG3 was 0.731 in hDWI and 0.699 in uhDWI ( = 0.161).

CONCLUSION

uhDWI suppressed background signal better than hDWI, but did not contribute to increased diagnostic performance in PC.

ADVANCES IN KNOWLEDGE

Compared with hDWI, uhDWI could not contribute to increased diagnostic performance in PC.

摘要

目的

高 b 值扩散加权成像(hDWI)的 b 值为 2000s/mm²,在良性和恶性组织之间提供的图像对比度不足,并且前列腺癌(PC)的 Gleason 分级(GG)之间的表观扩散系数(ADC)重叠。我们比较了超高 b 值 DWI(uhDWI)与 hDWI 在 PC 检出率和区分 PC 侵袭性方面的图像质量和诊断能力。

方法

49 例 PC 患者接受了 3T 多参数 MRI 检查。采集单激发回波平面 DWI,b 值分别为 0、2000 和 3000s/mm²。采用 4 分制评估前列腺解剖变形(AD)、良性前列腺信号强度(PSI)和病灶显影评分(LCS);测量病灶(lADC)和周围良性区域(bADC)的信噪比、对比噪声比和平均 ADC(×10mm/s)。

结果

uhDWI 的 PSI 显著低于 hDWI(<0.001)。uhDWI 和 hDWI 的 AD、LCS、信噪比和对比噪声比均无差异(均>0.05)。相比之下,uhDWI 和 hDWI 中 lADC 均显著低于 bADC(均<0.001)。在比较≤GG2 级肿瘤和≥GG3 级肿瘤的 lADC 时,uhDWI 和 hDWI 均有显著差异(=0.007 和=0.021)。hDWI 区分≤GG2 级肿瘤和≥GG3 级肿瘤的 AUC 为 0.731,uhDWI 为 0.699(=0.161)。

结论

uhDWI 对背景信号的抑制优于 hDWI,但在 PC 诊断性能的提高方面没有帮助。

知识的进步

与 hDWI 相比,uhDWI 不能提高 PC 的诊断性能。

相似文献

本文引用的文献

7
MRI-Targeted or Standard Biopsy for Prostate-Cancer Diagnosis.MRI 靶向或标准活检用于前列腺癌诊断。
N Engl J Med. 2018 May 10;378(19):1767-1777. doi: 10.1056/NEJMoa1801993. Epub 2018 Mar 18.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验