• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Complete self-calibration compact binary magneto-optic rotator based Mueller matrix polarimetry.

作者信息

Hua Peidong, Ding Zhenyang, Wang Chenhuan, Liu Kun, Jiang Junfeng, Yu Yin, Steve Yao X, Liu Tiegen

出版信息

Opt Express. 2021 Sep 13;29(19):30392-30408. doi: 10.1364/OE.439062.

DOI:10.1364/OE.439062
PMID:34614764
Abstract

Magneto-optic (MO) based Mueller matrix polarimetry (MMP) has several advantages of compact size, no-mechanical movement and high speed. Inaccuracies of components in the polarization state generator (PSG) optical parameters will influence the measurement accuracy of MMP. In this paper, we present a PSG self-calibration method in the compact MMP based on binary MO polarization rotators. Since PSG can generate enough numbers of non-degenerate polarization states, the optical parameters in PSG and the Mueller matrix of the sample can totally be numerically solved, which realizes a self-calibration in the PSG. Combining the previous self-calibration method in polarization state analyzer (PSA), we realize a complete self-calibration compact MO based MMP. Based on the numerical simulation results, the errors of measured phase retardance and optical axis of the sample decrease two to three orders of magnitude after applying the PSG self-calibration method. In experimental results of a variable retarder as a sample, the Euclidean distance of retardance between the measurement and reference curves comparing PSG self-calibration with no PSG self-calibration can be reduced from 0.035 rad to 0.033 rad and the Euclidean distance of optical axis can be reduced from 3.39° to 1.51°. Compared with the experimental results, the numerical simulation results more accurately verify the performance of the presented PSG self-calibration method without being influenced by other errors because the Mueller matrix of the sample is known and the error source only comes from these components in PSG.

摘要

相似文献

1
Complete self-calibration compact binary magneto-optic rotator based Mueller matrix polarimetry.
Opt Express. 2021 Sep 13;29(19):30392-30408. doi: 10.1364/OE.439062.
2
Analysis of experimental errors in Mueller matrix channeled polarimeters.穆勒矩阵通道偏振计实验误差分析
Appl Opt. 2021 Jun 20;60(18):5456-5464. doi: 10.1364/AO.430923.
3
Permitted experimental errors for optimized variable-retarder Mueller-matrix polarimeters.优化可变延迟器穆勒矩阵偏振仪的允许实验误差。
Opt Express. 2018 May 28;26(11):13693-13704. doi: 10.1364/OE.26.013693.
4
Mid-infrared Mueller ellipsometer with pseudo-achromatic optical elements.带有伪消色差光学元件的中红外穆勒椭圆偏振仪。
Appl Opt. 2015 Apr 1;54(10):2776-85. doi: 10.1364/AO.54.002776.
5
Binary classification of Mueller matrix images from an optimization of Poincaré coordinates.基于庞加莱坐标优化的穆勒矩阵图像二分类
J Opt Soc Am A Opt Image Sci Vis. 2017 Jun 1;34(6):983-990. doi: 10.1364/JOSAA.34.000983.
6
Modulus design multiwavelength polarization microscope for transmission Mueller matrix imaging.用于传输 Mueller 矩阵成像的模数设计多波长偏振显微镜。
J Biomed Opt. 2018 Jan;23(1):1-8. doi: 10.1117/1.JBO.23.1.016007.
7
Single-pulse, Kerr-effect Mueller matrix LiDAR polarimeter.
Opt Express. 2020 Apr 27;28(9):13694-13713. doi: 10.1364/OE.388565.
8
Differentiating characteristic microstructural features of cancerous tissues using Mueller matrix microscope.使用穆勒矩阵显微镜区分癌组织的特征性微观结构特征。
Micron. 2015 Dec;79:8-15. doi: 10.1016/j.micron.2015.07.014. Epub 2015 Aug 3.
9
General and self-consistent method for the calibration of polarization modulators, polarimeters, and mueller-matrix ellipsometers.用于校准偏振调制器、旋光仪和穆勒矩阵椭偏仪的通用且自洽的方法。
Appl Opt. 1999 Jun 1;38(16):3490-502. doi: 10.1364/ao.38.003490.
10
Eigenvalue calibration method for dual rotating-compensator Mueller matrix polarimetry.双旋转补偿器 Mueller 矩阵偏振光度法的特征值校准方法。
Opt Lett. 2021 Sep 15;46(18):4618-4621. doi: 10.1364/OL.437542.