Bundgaard A, Schmidt A
Eur J Respir Dis Suppl. 1986;143:11-3.
The reproducibility of the changes in FEV, induced by inhalation of histamine, was studied in adult asthmatics. Histamine was inhaled from a Hudson nebulizer, delivering 0.3 ml/min, at tidal breathing through one minute. FEV was measured immediately before and two minutes after cessation of the inhalation. Identical concentrations of histamine were inhaled by the individual patient on every challenge. Reproducibility was studied on the same day, with one day inbetween the histamine challenges and with 12 weeks inbetween two challenges. When reproducibility during the same day was studied an average fall in FEV of 34% was found after the first inhalation and 34% decrease was found after the second challenge. When histamine challenge were done on two following days the fall in FEV was 25% on the first day and 28% on the second day. The average fall in FEV was 34% and 28% when reproducibility was studied with an interval of 12 weeks. No statistically significant difference was found between any of the compared challenges.
在成年哮喘患者中研究了吸入组胺引起的第一秒用力呼气容积(FEV₁)变化的可重复性。通过Hudson雾化器以0.3毫升/分钟的流速在潮式呼吸时吸入组胺1分钟。在吸入停止前及停止后2分钟立即测量FEV₁。每位患者每次激发时吸入相同浓度的组胺。在同一天研究可重复性,组胺激发之间间隔1天,两次激发之间间隔12周。当在同一天研究可重复性时,第一次吸入后FEV₁平均下降34%,第二次激发后下降34%。当在连续两天进行组胺激发时,第一天FEV₁下降25%,第二天下降28%。当间隔12周研究可重复性时,FEV₁平均下降34%和28%。在任何比较的激发之间未发现统计学上的显著差异。