Suppr超能文献

用于现场快速评估混凝土结构中氯化物污染的垂直流纸传感器

Vertical-Flow Paper Sensor for On-Site and Prompt Evaluation of Chloride Contamination in Concrete Structures.

作者信息

Colozza Noemi, Tazzioli Sara, Sassolini Alessandro, Agosta Lorenzo, di Monte Maria Giuseppina, Hermansson Kersti, Arduini Fabiana

机构信息

Department of Chemical Science and Technologies, University of Rome Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy.

ARPA Lazio, Via Salaria per L'Aquila 6-8, 02100 Rieti, Italy.

出版信息

Anal Chem. 2021 Nov 2;93(43):14369-14374. doi: 10.1021/acs.analchem.1c03363. Epub 2021 Oct 20.

Abstract

Corrosion occurring in reinforced concrete has turned into a primary concern of the current century, concrete being the most ubiquitous and predominant material used in the construction industry. Among the many interrelated processes that trigger corrosion of metallic reinforcements, the penetration of chloride ions into the concrete matrix is the most insidious threat. Herein, we developed the first electrochemical device entirely made of paper that allows for the direct, prompt, and noninvasive evaluation of free chloride ion contamination in concrete-based constructions. Our device is based on a three-layer wax-modified filter paper, consisting of two Ag/AgCl screen-printed electrodes that are interfaced by a junction pad in a sandwich-like configuration. Filter paper allows for generating a vertical-flow potentiometric device capable of measuring the electrochemical potential between two solutions containing different concentrations of chloride ions, which are separately drop-cast on the top and bottom layers. After demonstrating the analytical performance of the device, the same principle was applied to the evaluation of the chloride contents in different concrete samples, exploiting paper as a suitable interfacing material for potentiometric measurements on the cement solid surface. Laboratory-prepared concrete samples with known chloride contents were first assessed, and then, the paper-based vertical-flow device was applied to real concrete structures at the Giacomo Manzù Museum (Ardea, Italy) for the evaluation of chloride contamination caused by the proximity to the seaside. The capability of our device to provide timely warning of the risk conditions of concrete-based artifacts was demonstrated.

摘要

钢筋混凝土中的腐蚀已成为本世纪的一个主要问题,混凝土是建筑行业中使用最广泛、最主要的材料。在引发金属钢筋腐蚀的众多相互关联的过程中,氯离子渗入混凝土基体是最隐蔽的威胁。在此,我们开发了首个完全由纸张制成的电化学装置,可对混凝土结构中的游离氯离子污染进行直接、快速且非侵入性的评估。我们的装置基于三层蜡改性滤纸,由两个Ag/AgCl丝网印刷电极组成,它们通过一个连接垫以三明治状结构连接。滤纸能够制成一种垂直流电位测量装置,该装置能够测量分别滴铸在顶层和底层的两种含有不同浓度氯离子的溶液之间的电化学电位。在展示了该装置的分析性能后,利用纸张作为在水泥固体表面进行电位测量的合适界面材料,将相同原理应用于评估不同混凝土样品中的氯化物含量。首先对实验室制备的已知氯化物含量的混凝土样品进行评估,然后,将基于纸张的垂直流装置应用于意大利阿尔代亚的贾科莫·曼祖博物馆的实际混凝土结构,以评估因靠近海边而造成的氯化物污染。我们的装置能够对基于混凝土的文物的风险状况提供及时预警。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验