Department of Ophthalmology and Vision Science, Eye and ENT Hospital of Fudan University, Shanghai, China; NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, and Key Laboratory of Visual Impairment and Restoration of Shanghai, Shanghai, China.
J Cataract Refract Surg. 2021 Nov 1;47(11):1423-1429. doi: 10.1097/j.jcrs.0000000000000649.
To investigate the accuracy of intraocular lens (IOL) formulas for the prediction of postoperative refraction in lens subluxation in Marfan syndrome.
Eye and ENT Hospital of Fudan University, Shanghai, China.
Consecutive retrospective clinical observational case series.
60 eligible eyes with lens subluxation from 39 young patients with Marfan syndrome (8.53 ± 4.38 years) underwent phacoemulsification combined with single-eyelet modified capsular tension ring (MCTR) and IOL implantation. The prediction error values with mean zero out (relative prediction error) and their absolute values (AE) were calculated.
Generally, the SRK/T formula with Wang-Koch (WK) adjustment had the lowest median AE at 0.418 diopters (D), and the Holladay 1 with WK adjustment had the lowest mean AE at 0.499 D. The median AE of the other 10 formulas, in order from lowest to highest, were Haigis with WK (0.494 D), Holladay 1 with WK (0.495 D), Hoffer Q with WK (0.508 D), Haigis (0.525 D), T2 (0.542 D), Hoffer Q (0.624 D), SRK/T and Holladay 1 (0.660 D), Super (0.680 D), and Barrett Universal II (0.714 D) formulas. Haigis formula was found to be statistically significantly different from SRK/T, Holladay 1, and Barrett Universal II (all 3 P < .001) but not Hoffer Q (P = .236) formula.
The Haigis formula was recommended for young Marfan lens subluxation patients with in-the-bag IOLs and scleral-sutured single-eyelet MCTR implantation. WK adjustments were successful in those cases where the axial length was longer than 25.0 mm.
研究眼内透镜(IOL)公式在马凡综合征晶状体半脱位患者术后屈光预测中的准确性。
中国上海复旦大学眼耳鼻喉科医院。
连续回顾性临床观察病例系列。
39 例马凡综合征年轻患者(8.53±4.38 岁)的 60 只晶状体半脱位眼接受了超声乳化白内障吸除术联合单眼环扎式改良囊袋张力环(MCTR)和 IOL 植入术。计算预测误差值的平均值为零(相对预测误差)及其绝对值(AE)。
一般来说,SRK/T 公式与 Wang-Koch(WK)调整后的中位数 AE 最低,为 0.418 屈光度(D),Holladay 1 公式与 WK 调整后的平均值 AE 最低,为 0.499 D。其他 10 种公式的中位数 AE,从低到高依次为 Haigis 公式与 WK(0.494 D)、Holladay 1 公式与 WK(0.495 D)、Hoffer Q 公式与 WK(0.508 D)、Haigis 公式(0.525 D)、T2 公式(0.542 D)、Hoffer Q 公式(0.624 D)、SRK/T 公式和 Holladay 1 公式(0.660 D)、Super 公式(0.680 D)和 Barrett Universal II 公式(0.714 D)。发现 Haigis 公式与 SRK/T、Holladay 1 和 Barrett Universal II 公式有统计学显著差异(均 P <.001),但与 Hoffer Q 公式无差异(P =.236)。
对于袋内 IOL 和巩膜缝线单眼环扎式 MCTR 植入的年轻马凡综合征晶状体半脱位患者,推荐使用 Haigis 公式。在轴向长度大于 25.0 mm 的情况下,WK 调整是成功的。