Suppr超能文献

拔罐最佳强度和时间,以尽量减少可能的机械性皮肤变形。

Optimal intensity and duration of cupping for minimizing possible mechanical skin deformation.

机构信息

Robotics R & BD Group, Korea Institute of Industrial Technology, Ansan 15588, Republic of Korea.

Department of Robotics and Virtual Engineering, University of Science and Technology, Ansan 15588, Republic of Korea.

出版信息

J Tradit Chin Med. 2021 Oct;41(5):817-825. doi: 10.19852/j.cnki.jtcm.2021.05.015.

Abstract

OBJECTIVE

To identify the optimal intensity and duration of cupping that would minimize mechanical skin deformation.

METHODS

We developed an optical measurement probe and system for measuring skin color values in real time. We applied cupping at the following five Bladder Meridian acupoints. To investigate optimal intensity, negative pressure intensity was increased every 2 min up to 80 kPa. To investigate optimal time, 10 measurement sites were selected and negative pressure intensities of 30, 60, and 80 kPa were applied for 5 min each. Skin color information was analyzed by the following skin color values: red color saturation, erythema index, and melanin index.

RESULTS

The red color saturation and erythema index increased steadily up to 60 kpa negative pressure intensity, then decreased between 60 and 80 kPa. Therefore, maximal values were observed at 60 kPa. The melanin index consistently increased with increasing negative pressure intensity. The red color saturation and erythema index did not change after 20 s at 60 kPa negative pressure intensity. For negative pressure intensities below 80 kPa, significant changes in melanin index were not observed after 20 s. At 80 kPa negative pressure intensity, the melanin index exhibited an increasing pattern for 200 s, then showed no changes.

CONCLUSIONS

To minimize skin deformation, 60 kPa and 20 s were the appropriate intensity and duration when using red color saturation and erythema index as diagnostic indexes. Because of the increasing pattern up to 80 kPa negative pressure intensity, the optimal intensity of melanin index could not be determined. When applying 80 kPa negative pressure intensity and using melanin index as the diagnostic index, we recommend a duration of 200 s.

摘要

目的

确定能够将皮肤机械变形最小化的拔罐最佳强度和时间。

方法

我们开发了一种光学测量探头和系统,用于实时测量皮肤颜色值。我们在以下五个膀胱经穴位应用拔罐。为了研究最佳强度,每隔 2 分钟将负压强度增加到 80kPa。为了研究最佳时间,选择了 10 个测量点,每个点分别施加 30、60 和 80kPa 的负压强度 5 分钟。通过以下皮肤颜色值分析皮肤颜色信息:红色饱和度、红斑指数和黑色素指数。

结果

红色饱和度和红斑指数随着 60kPa 负压强度的增加而稳定增加,然后在 60-80kPa 之间下降。因此,在 60kPa 时观察到最大值。黑色素指数随着负压强度的增加而持续增加。在 60kPa 负压强度下,20 秒后红色饱和度和红斑指数没有变化。在 80kPa 以下的负压强度下,20 秒后黑色素指数没有明显变化。在 80kPa 负压强度下,黑色素指数在 200 秒内呈上升趋势,然后保持不变。

结论

为了将皮肤变形最小化,当使用红色饱和度和红斑指数作为诊断指标时,60kPa 和 20s 是合适的强度和时间。由于在 80kPa 负压强度下呈上升趋势,因此无法确定黑色素指数的最佳强度。当应用 80kPa 负压强度并使用黑色素指数作为诊断指标时,我们建议持续时间为 200 秒。