Six patients were included to retrospectively review the preliminary efficacy and safety of mechanical thrombectomy using kissing Y-Solitaire as a rescue treatment. This technique was performed following failed single Solitaire thrombectomy in 5 patients (5/6), and the remaining patient (1/6) underwent unsuccessful AngioJet thrombectomy (Boston Scientific, Marlborough, Massachusetts). The ranges of the target vessel clot length and diameter were 4.9-6.9 mm and 27-38 mm, respectively. Technical success was achieved in all patients (6/6). They (6/6) had notable acute limb ischemia (ALI) symptom relief after 1 or 2 passes of retrieval, and clinical success was achieved in all patients (6/6). No complications were observed other than reversible vasospasm in 1 patient (1/6). Amputation or death did not occur. Mechanical revascularization with the use of kissing Y-Solitaire seems to be a potentially rapid, safe, and effective modality for selected patients with refractory short-segment occlusion of ALI secondary to popliteal and infrapopliteal arteries.

摘要

纳入 6 例患者,回顾性分析应用 Y 型 Solitaire 支架取栓术作为补救性治疗的初步疗效和安全性。该技术应用于 5 例(5/6)患者的单纯 Solitaire 取栓术失败后,其余 1 例(1/6)患者行 AngioJet 血栓切除术(波士顿科学公司,马萨诸塞州马尔伯勒)失败。目标血管血栓长度和直径范围分别为 4.9-6.9mm 和 27-38mm。所有患者(6/6)均达到技术成功。在 1 或 2 次取栓后,所有患者(6/6)的急性肢体缺血(ALI)症状均显著缓解,所有患者(6/6)均达到临床成功。除 1 例(1/6)患者出现可逆性血管痉挛外,无其他并发症。对于因腘动脉和胫后动脉引起的难治性短节段 ALI 的选择性患者,使用 Y 型 Solitaire 支架取栓术似乎是一种快速、安全且有效的机械再通方式。