Department of Pharmacy, Pharmaceutical Technology and Biopharmaceutics, Ludwig-Maximilians-Universitaet Muenchen, 81377, Munich, Germany.
Technical Research and Development, Novartis Pharma AG, 4002, Basel, Switzerland.
Pharm Res. 2021 Nov;38(11):1977-1989. doi: 10.1007/s11095-021-03117-6. Epub 2021 Nov 2.
Scale-down devices (SDD) are designed to simulate large-scale thawing of protein drug substance, but require only a fraction of the material. To evaluate the performance of a new SDD that aims to predict thawing in large-scale 2 L bottles, we characterised 3D temperature profiles and changes in concentration and density in comparison to 125 mL and 2 L bottles. Differences in diffusion between a monoclonal antibody (mAb) and histidine buffer after thawing were examined.
Temperature profiles at six distinct positions were recorded with type T thermocouples. Size-exclusion chromatography allowed quantification of mAb and histidine. Polysorbate 80 was quantified using a fluorescent dye assay. In addition, the solution's density at different locations in bottles and the SDD was identified.
The temperature profiles in the SDD and the large-scale 2 L bottle during thawing were similar. Significant concentration gradients were detected in the 2 L bottle leading to marked density gradients. The SDD slightly overestimated the dilution in the top region and the maximum concentrations at the bottom. Fast diffusion resulted in rapid equilibration of histidine.
The innovative SDD allows a realistic characterisation and helps to understand thawing processes of mAb solutions in large-scale 2 L bottles. Only a fraction of material is needed to gain insights into the thawing behaviour that is associated with several possible detrimental limitations.
缩比设备(SDD)旨在模拟大规模蛋白药物制剂的解冻过程,但仅需使用少量的物料。为了评估旨在预测 2L 大规模瓶中解冻过程的新型 SDD 的性能,我们对 3D 温度分布以及浓度和密度的变化进行了表征,将其与 125mL 和 2L 瓶进行了比较。还研究了解冻后单克隆抗体(mAb)和组氨酸缓冲液之间的扩散差异。
使用 T 型热电偶记录了六个不同位置的温度分布。使用尺寸排阻色谱法对 mAb 和组氨酸进行定量。使用荧光染料测定法对聚山梨酯 80 进行定量。此外,还确定了不同位置瓶和 SDD 中溶液的密度。
解冻过程中 SDD 和 2L 大瓶中的温度分布相似。在 2L 瓶中检测到明显的浓度梯度,导致明显的密度梯度。SDD 略微高估了顶部区域的稀释度和底部的最大浓度。快速扩散导致组氨酸迅速达到平衡。
创新型 SDD 可实现对 mAb 溶液在 2L 大瓶中解冻过程的真实特征化,并有助于理解其解冻过程。仅需使用少量物料即可深入了解与多种潜在不利限制相关的解冻行为。