Division of HIV, Infectious Diseases, and Global Medicine, Department of Medicine, University of California, San Francisco, CA, United States.
CAMAG DBS Laboratory, Muttenz, Switzerland.
Alcohol. 2022 Feb;98:51-54. doi: 10.1016/j.alcohol.2021.11.001. Epub 2021 Nov 10.
Phosphatidylethanol (PEth) is a sensitive and specific biomarker of alcohol consumption in the prior 2-3 weeks. Standard, manual PEth testing using dried blood spots (DBS) is a multi-step time-consuming process. A novel, automated processing and testing method has been developed to decrease DBS processing and testing time. We conducted automated testing, using regioisomerically pure PEth reference material, on randomly selected DBS, which had previously been tested via manual methods and then stored for 3-6 years at -80 °C, to compare the results (PEth 16:0/18:1 homologue). We chose samples for re-testing using categories found in the literature as follows: 1) PEth <20 ng/mL; 2) PEth 20-200 ng/mL; 3) PEth >200-1000 ng/mL; 4) PEth >1000 ng/mL. We calculated agreement between the categories using the weighted kappa statistic (n = 49 DBS). We quantified agreement between continuous measures using the intraclass correlation coefficient (ICC), and further described the relationship between variables using Spearman correlation. The median PEth result was 155 ng/mL (interquartile range [IQR]: 1-1312 ng/mL) via automated methods and 98.8 ng/mL (IQR: 10.2-625.0 ng/mL) via manual methods. The weighted kappa comparing the automated to manual PEth results was 0.76 [95% Confidence Interval (CI): 0.66-0.86]. The ICC was 0.69 (95% CI: 0.54-0.79), and the Spearman correlation was 0.98 (95% CI: 0.95-0.99). While the new methods yielded somewhat higher PEth values, we found good to excellent agreement between clinically relevant PEth categories. Automated DBS processing and testing using new reference standards are promising methods for PEth testing.
磷脂酰乙醇(PEth)是一种敏感且特异的 2-3 周内饮酒的生物标志物。使用干血斑(DBS)的标准、手动 PEth 检测是一个多步骤、耗时的过程。现已开发出一种新型的自动处理和检测方法,以减少 DBS 的处理和检测时间。我们使用具有区域异构体纯 PEth 参考物质对随机选择的 DBS 进行了自动检测,这些 DBS 先前已经通过手动方法进行了检测,然后在-80°C 下储存了 3-6 年,以比较结果(PEth 16:0/18:1 同系物)。我们选择了使用文献中发现的类别进行重新测试的样本,如下所示:1)PEth <20ng/mL;2)PEth 20-200ng/mL;3)PEth >200-1000ng/mL;4)PEth >1000ng/mL。我们使用加权 kappa 统计量(n=49 个 DBS)来计算类别之间的一致性。我们使用组内相关系数(ICC)来量化连续测量之间的一致性,并使用 Spearman 相关性进一步描述变量之间的关系。通过自动方法得到的中位 PEth 结果为 155ng/mL(四分位距[IQR]:1-1312ng/mL),而通过手动方法得到的结果为 98.8ng/mL(IQR:10.2-625.0ng/mL)。自动方法与手动 PEth 结果的加权 kappa 比较为 0.76[95%置信区间(CI):0.66-0.86]。ICC 为 0.69(95%CI:0.54-0.79),Spearman 相关性为 0.98(95%CI:0.95-0.99)。虽然新方法得出的 PEth 值略高,但我们发现临床上相关的 PEth 类别之间具有良好到极好的一致性。使用新参考标准的自动 DBS 处理和检测是 PEth 检测的有前途的方法。