Suppr超能文献

初步评估 3D 打印版多伦多康复研究所手功能测试在脊髓损伤患者中的可靠性和有效性。

Preliminary evaluation of the reliability and validity of the 3D printed Toronto Rehabilitation Institute-Hand Function Test in individuals with spinal cord injury.

机构信息

KITE, Toronto Rehabilitation Institute - University Health Network, Toronto, Canada.

Rehabilitation Sciences Institute, University of Toronto, Toronto, Canada.

出版信息

J Spinal Cord Med. 2021;44(sup1):S225-S233. doi: 10.1080/10790268.2021.1961055.

Abstract

OBJECTIVE

The study objectives were to evaluate the inter-rater and intra-rater reliability; and criterion and construct validity of the 3D printed Toronto Rehabilitation Institute -Hand Function Test (3D TRI-HFT) in individuals with spinal cord injury (SCI).

DESIGN

Observational study.

SETTING

Inpatient Rehabilitation Hospital.

PARTICIPANTS

Four individuals with subacute and three individuals with chronic SCI.

INTERVENTIONS

Reliability and validity of the 3D TRI-HFT was assessed within two interventional studies.

OUTCOME MEASURES

Participants performed the 3D TRI-HFT, Graded Redefined Assessment of Strength, Sensibility and Prehension (GRASSP), Functional Independence Measure (FIM) and the Spinal Cord Independence Measure (SCIM) at baseline, after 20 and 40 sessions of therapy and at six month follow-up from baseline. 3D TRI-HFT assessments were graded at the time of performance and re-graded from the video recordings for purpose of reliability testing. Validity testing was done by comparing the scores on 3D TRI-HFT with the scores on the GRASSP, and the FIM and SCIM self care sub-scores.

RESULTS

The 3D TRI-HFT had high intra-rater and inter-rater reliability in sub-acute and chronic SCI with ICC values exceeding 0.99. Moderate to strong correlations were found between 3D TRI-HFT object manipulation scores and the FIM and SCIM self care sub-scores, with r values in the range of 0.7-0.8. Strong correlations were found between the various components of GRASSP and the 3D TRI-HFT, with r values exceeding 0.9.

CONCLUSIONS

The 3D TRI-HFT is a reliable and valid measure to assess unilateral hand gross motor function in individuals with SCI.

摘要

目的

本研究旨在评估 3D 打印多伦多康复研究所手功能测试(3D TRI-HFT)在脊髓损伤(SCI)患者中的评定者间信度、评定者内信度、效标效度和结构效度。

设计

观察性研究。

地点

住院康复医院。

参与者

4 例亚急性 SCI 患者和 3 例慢性 SCI 患者。

干预措施

在两项干预性研究中评估 3D TRI-HFT 的信度和效度。

结局指标

参与者在基线时、治疗 20 次和 40 次后以及从基线开始的 6 个月随访时,分别完成 3D TRI-HFT、重新定义的上肢力量、感觉和抓握评估(GRASSP)、功能独立性测量(FIM)和脊髓独立性测量(SCIM)。在进行 3D TRI-HFT 评估的同时进行分级,为了进行可靠性测试,从视频记录中重新分级。通过比较 3D TRI-HFT 评分与 GRASSP 评分以及 FIM 和 SCIM 自理子评分,进行有效性测试。

结果

3D TRI-HFT 在亚急性和慢性 SCI 中具有较高的评定者内和评定者间信度,ICC 值均超过 0.99。3D TRI-HFT 物体操作评分与 FIM 和 SCIM 自理子评分之间存在中度至高度相关性,r 值范围为 0.7-0.8。GRASSP 的各个分量与 3D TRI-HFT 之间存在很强的相关性,r 值超过 0.9。

结论

3D TRI-HFT 是一种可靠且有效的测量工具,可用于评估 SCI 患者的单侧手粗大运动功能。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/eda8/8604468/ab638e09268a/YSCM_A_1961055_F0001_OB.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验