PURPOSE

Reconstructive surgery after craniofacial trauma aim to restore orbital anatomy for function and aesthetic reasons. The purpose of this study is to improve postoperative orbital symmetry with the use of prebent prefabricated titanium implants.

METHODS

In this retrospective study, patients with combined unilateral medial wall and floor fractures who underwent orbital reconstruction surgery were selected. The angle of inferomedial orbital strut (AIOS) was measured at 3 standard locations on preoperative facial computed tomography guided scans of the nonfractured orbit in the coronal view and used as a guide to bend the prefabricated titanium implants intraoperatively. The corresponding values were measured on the postoperative computed tomography and compared for symmetry.

RESULTS

Out of 83 patients recruited for the study, 54 were in the prebent group while 29 were in the control group. All other demographics were similar among the 2 groups. Anterior AIOS has a difference of 4.9° between 2 orbits in the prebent group whereas a difference of 15.5° was noted in the nonprebent group. For middle AIOS, a difference of 4.7° was noted in the prebent group whereas nonprebent group had a difference of 14.1°. For posterior AIOS, the prebent group had a difference of 3.8° versus 14.1° in the nonprebent group. The difference in AIOS at all 3 points between the prebent and nonprebent group were significant.

CONCLUSIONS

Anatomical prefabricated titanium plates are versatile implants that facilitate orbital reconstruction. Prebending of these implants according to the fellow orbit can achieve better surgical outcomes in a cost-effective manner.

摘要

目的

颅面外伤后的重建手术旨在恢复眶部解剖结构,以达到功能和美学方面的目的。本研究的目的是使用预弯预制钛植入物来改善术后眶部对称性。

方法

在这项回顾性研究中,选择了接受单侧内侧壁和地板骨折眶重建手术的患者。在冠状位上对未骨折眶的术前面部计算机断层扫描引导扫描进行测量,以测量内下眶支柱的角度(AIOS),并在术中作为指导来弯曲预制钛植入物。在术后 CT 上测量相应的值,并比较其对称性。

结果

在纳入研究的 83 名患者中,54 名患者在预弯组,29 名患者在对照组。两组的其他所有人口统计学特征均相似。在预弯组,两个眶之间的前 AIOS 差异为 4.9°,而非预弯组的差异为 15.5°。对于中 AIOS,预弯组的差异为 4.7°,而非预弯组的差异为 14.1°。对于后 AIOS,预弯组的差异为 3.8°,而非预弯组的差异为 14.1°。在预弯组和非预弯组之间,所有 3 个点的 AIOS 差异均有统计学意义。

结论

解剖预制钛板是一种多功能植入物,可促进眼眶重建。根据对侧眼眶对这些植入物进行预弯,可以以经济有效的方式实现更好的手术效果。