Voronin A V, Malkova T L, Synbulatov I V
Samara State Medical University, Samara, Russia.
Perm State Pharmaceutical Academy, Perm, Russia.
Sud Med Ekspert. 2021;64(6):39-42. doi: 10.17116/sudmed20216406139.
The objective of this work is to evaluate the possibility of biological fluids sample preparation in forensic toxicology using a molecularly imprinted sorbent based on acrylic acid derivatives. Phenylpiracetam has similar physicochemical properties to those of pyrrolidinophenone derivatives and reproduces their behavior during solid-phase extraction. The phenylpiracetam recovery from blood and urine model samples is 75% for concentration range of 100.0-6000.0 ng/ml. The accuracy of phenylpiracetam extraction does not exceed ±12% for blood samples and ±6% for urine samples. The repeatability is no more than 16% and 13% for blood and urine samples, respectively. A study of the cross-reactivity of the molecularly imprinted sorbent with some drugs showed the selectivity of the sample preparation procedure.
这项工作的目的是评估在法医毒理学中使用基于丙烯酸衍生物的分子印迹吸附剂制备生物流体样本的可能性。苯吡乙酰胺具有与吡咯烷酮衍生物相似的物理化学性质,并在固相萃取过程中重现它们的行为。对于浓度范围为100.0 - 6000.0 ng/ml的血液和尿液模型样本,苯吡乙酰胺的回收率为75%。血液样本中苯吡乙酰胺提取的准确度不超过±12%,尿液样本不超过±6%。血液和尿液样本的重复性分别不超过16%和13%。对分子印迹吸附剂与某些药物的交叉反应性研究表明了样本制备程序的选择性。