From July 2020 to June 2021, patients in Jiangyin Hospital Affiliated to Nantong University who met the enrollment criteria were treated with the fishhook-like device during the operation to suture the postoperative wound (group A). Patients with similar conditions and similar size wounds who were treated with a "purse-string suture" to suture the wounds were retrospectively analyzed as the control group (group B). Difference in the suture rate, adverse events, time required for suturing, and number of metal clips were compared between the two groups. The time required for suturing was (7.83±2.41) min in group A and (11.00±3.31) min in group B. The difference was statistically significant (=0.002). The number of metal clamps used in group A averaged 7.17 pieces/case, and the number of metal clamps used in group B averaged 7.06 pieces/case. The difference was not statistically significant (>0.05).The traction metal clip with the fishhook-like device is ingeniously designed and easy to operate. It has a good suture effect on the wound after endoscopic resection and effectively prevents postoperative adverse events.
2020年7月至2021年6月,南通大学附属江阴医院中符合纳入标准的患者在手术中采用鱼钩状装置缝合术后伤口(A组)。对采用“荷包缝合”缝合伤口的病情及伤口大小相似的患者进行回顾性分析作为对照组(B组)。比较两组的缝合率、不良事件、缝合所需时间及金属夹数量。A组缝合所需时间为(7.83±2.41)分钟,B组为(11.00±3.31)分钟。差异有统计学意义(=0.002)。A组平均每例使用金属夹7.17枚,B组平均每例使用金属夹7.06枚。差异无统计学意义(>0.05)。带鱼钩状装置的牵引金属夹设计巧妙,操作简便。对内镜切除术后的伤口缝合效果良好,有效预防术后不良事件。