Suppr超能文献

无眼球眼眶中使用圆锥形或球形植入物时的运动幅度。

Amplitude of movements with conical or spherical implants in anophthalmic socket.

作者信息

Bigheti Carolina Pereira, Peitl Oscar, Ferreira Gabriel de Almeida, Schellini Silvana Artioli

机构信息

Department of Ophthalmology, Medical School (FMB), São Paulo State University (Unesp), Botucatu, Brasil.

Department of Materials Engineering, Federal University of São Carlos (Ufscar), São Carlos, Brasil.

出版信息

Orbit. 2022 Dec;41(6):708-716. doi: 10.1080/01676830.2021.1998914. Epub 2021 Nov 28.

Abstract

PURPOSE

To evaluate the amplitude of movement in anophthalmic sockets reconstructed with conical or spherical orbital implants with and without an external ocular prosthesis (EOP), and whether the fornix depth could play a role.

METHODS

Prospective observational study involving unilateral anophthalmic sockets evaluated the amplitude of movement with conical (20 subjects) or spherical (16) non-porous orbital implants, with and without an EOP, having the contralateral eye as the control group. Standardized photographs were obtained in the four gaze directions and measurements were performed using the Image J software. The upper and lower fornix depths were measured using rulers.

RESULTS

Compared to the contralateral eye, the median movement amplitude without EOP was smaller with conical implants in supraduction (-0.88 mm, p=0.008), abduction (-2.26 mm, p<0.001) and adduction (-0.91 mm, p=0.008). Spherical implants had reduced movement only in abduction (-2.63 mm, p<0.001). Conical and spherical implants had similar amplitudes of movement in all versions, and were always smaller compared to the control. The median movement amplitude with the EOP was -3.05 mm (p=0.001) than without the EOP in abduction and -2.07 mm (p=0.020) in adduction, regardless of implant format. The fornix depth did not affect the orbital implants or EOP movement amplitude's median.

CONCLUSION

Conical and spherical implants provide similar amplitude of movement and fornix depth did not have an influence on it. The amplitude of movement was significantly limited compared to the contralateral eye and was even more reduced if the EOP was in place with conical or spherical implant formats.

摘要

目的

评估使用圆锥形或球形眼眶植入物重建的无眼球眼眶在有和没有眼外假体(EOP)情况下的运动幅度,以及穹窿深度是否起作用。

方法

一项前瞻性观察性研究,涉及单侧无眼球眼眶,以对侧眼作为对照组,评估使用圆锥形(20例受试者)或球形(16例)无孔眼眶植入物在有和没有EOP情况下的运动幅度。在四个注视方向获取标准化照片,并使用Image J软件进行测量。使用尺子测量上下穹窿深度。

结果

与对侧眼相比,在无EOP的情况下,圆锥形植入物在向上注视(-0.88mm,p = 0.008)、外展(-2.26mm,p < 0.001)和内收(-0.91mm,p = 0.008)时的运动幅度中位数较小。球形植入物仅在外展时运动减少(-2.63mm,p < 0.001)。圆锥形和球形植入物在所有方向上的运动幅度相似,且与对照组相比始终较小。无论植入物类型如何,在有EOP时外展的运动幅度中位数比无EOP时小-3.05mm(p = 0.001),内收时小-2.07mm(p = 0.020)。穹窿深度不影响眼眶植入物或EOP运动幅度的中位数。

结论

圆锥形和球形植入物提供相似的运动幅度,穹窿深度对其没有影响。与对侧眼相比,运动幅度明显受限,并且如果使用圆锥形或球形植入物形式的EOP,运动幅度会进一步减小。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验