Suppr超能文献

采用多孔聚乙烯球形和四动度植入物的眼球摘除术后眼窝中的人工眼振幅及特征

Artificial eye amplitudes and characteristics in enucleated socket with porous polyethylene spherical and quad-motility implant.

作者信息

Lucci Lucia Miriam Dumont, Höfling-Lima Ana Luisa, Erwenne Clélia Maria, Toledo Cassano Emanuela Martins de

机构信息

Setor de Plástica, Departamento de Oftalmologia, Faculdade de Medicina do ABC, São Paulo, SP, Brazil.

出版信息

Arq Bras Oftalmol. 2007 Sep-Oct;70(5):831-8. doi: 10.1590/s0004-27492007000500019.

Abstract

PURPOSE

To compare artificial eye amplitudes in enucleated socket with porous polyethylene either spherical or quad-motility implant and study the characteristics of artificial eyes fit with the two orbital implants.

METHODS

A total of 21 patients were prospectively studied who underwent enucleation because of an intraocular melanoma and the randomization defined a porous polyethylene either spherical or quad-motility orbital implant. Measurements of the amplitude of the artificial eye were obtained with prism and digital photos. The software Scion Image analyzed the digital photos (www.scioncorp.com) and the quantitative data were allocated to groups. The measurements (height, length, thickness) and weight of the 21 artificial eyes were analyzed. Student's t-test was performed to determine the significance of difference between groups (p<0.05).

RESULTS

There was no statistically significant difference of the artificial eye amplitude analyzed by means of prisms between both orbital implants (p>0.05 for all directions). On analyzing the digital photos, the artificial eye with spherical implant showed higher artificial eye amplitude downward (p=0.009) among patients older than 55 years old, rightward (p=0.036) and downward (p=0.008) among the 9 patients with enucleated right eye. Height and length were similar in the 21 artificial eyes but those artificial eyes fit with quad-motility orbital implants were statistically significant thicker (p<0.001) and heavier (p=0.001).

CONCLUSIONS

The similar amplitude of movement of artificial eyes was observed with both spherical and quad-motility orbital implants. Artificial eyes fit with quad-motility orbital implant are significantly thicker and heavier than those fit with spherical orbital implant.

摘要

目的

比较眼球摘除术后眼眶内植入球形或四向运动型多孔聚乙烯义眼座时的义眼活动幅度,并研究与这两种眼眶植入物适配的义眼的特点。

方法

前瞻性研究了21例因眼内黑色素瘤接受眼球摘除术的患者,随机植入球形或四向运动型多孔聚乙烯眼眶植入物。通过棱镜和数码照片测量义眼活动幅度。使用Scion Image软件(www.scioncorp.com)分析数码照片,并将定量数据分组。分析了21只义眼的测量值(高度、长度、厚度)和重量。采用学生t检验确定组间差异的显著性(p<0.05)。

结果

两种眼眶植入物通过棱镜分析的义眼活动幅度无统计学显著差异(所有方向p>0.05)。分析数码照片时,球形植入物的义眼在55岁以上患者中向下活动幅度更高(p=0.009),在9例右眼摘除患者中向右(p=0.036)和向下(p=0.008)活动幅度更高。21只义眼的高度和长度相似,但与四向运动型眼眶植入物适配的义眼在统计学上显著更厚(p<0.001)、更重(p=0.001)。

结论

球形和四向运动型眼眶植入物的义眼活动幅度相似。与四向运动型眼眶植入物适配的义眼比与球形眼眶植入物适配的义眼显著更厚、更重。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验