升主动脉假体移植物对心脏磁共振成像术后早期降主动脉生物力学的影响。

Impact of ascending aortic prosthetic grafts on early postoperative descending aortic biomechanics on cardiac magnetic resonance imaging.

机构信息

Department of Cardiothoracic Surgery, Weill Cornell Medicine, New York, NY, USA.

Department of Bioengineering, Polytecnico University, Milan, Italy.

出版信息

Eur J Cardiothorac Surg. 2022 Mar 24;61(4):860-868. doi: 10.1093/ejcts/ezab501.

Abstract

OBJECTIVES

Among patients with ascending thoracic aortic aneurysms, prosthetic graft replacement yields major benefits but risk for recurrent aortic events persists for which mechanism is poorly understood. This pilot study employed cardiac magnetic resonance to test the impact of proximal prosthetic grafts on downstream aortic flow and vascular biomechanics.

METHODS

Cardiac magnetic resonance imaging was prospectively performed in patients with thoracic aortic aneurysms undergoing surgical (Dacron) prosthetic graft implantation. Imaging included time resolved (4-dimensional) phase velocity encoded cardiac magnetic resonance for flow quantification and cine-cardiac magnetic resonance for aortic wall distensibility/strain.

RESULTS

Twenty-nine patients with thoracic aortic aneurysms undergoing proximal aortic graft replacement were studied; cardiac magnetic resonance was performed pre- [12 (4, 21) days] and postoperatively [6.4 (6.2, 7.2) months]. Postoperatively, flow velocity and wall shear stress increased in the arch and descending aorta (P < 0.05); increases were greatest in hereditary aneurysm patients. Global circumferential strain correlated with wall shear stress (r = 0.60-0.72, P < 0.001); strain increased postoperatively in the native descending and thoraco-abdominal aorta (P < 0.001). Graft-induced changes in biomechanical properties of the distal native ascending aorta were associated with post-surgical changes in descending aortic wall shear stress, as evidenced by correlations (r = -0.39-0.52; P ≤ 0.05) between graft-induced reduction of ascending aortic distensibility and increased distal native aortic wall shear stress following grafting.

CONCLUSIONS

Prosthetic graft replacement of the ascending aorta increases downstream aortic wall shear stress and strain. Postoperative increments in descending aortic wall shear stress correlate with reduced ascending aortic distensibility, suggesting that grafts provide a nidus for high energy flow and adverse distal aortic remodelling.

摘要

目的

在患有升主动脉瘤的患者中,人造移植物置换可带来显著益处,但仍存在复发性主动脉事件的风险,其机制尚不清楚。本研究采用心脏磁共振技术,旨在检测近端人造移植物对下游主动脉血流和血管生物力学的影响。

方法

前瞻性纳入行胸主动脉瘤手术(Dacron 人造移植物植入)的患者,进行心脏磁共振成像检查。成像包括时间分辨(4 维)相位速度编码心脏磁共振以量化血流和电影心脏磁共振以评估主动脉壁延展性/应变。

结果

研究纳入 29 例接受近端主动脉移植物置换的胸主动脉瘤患者,分别在术前[12(4,21)天]和术后[6.4(6.2,7.2)个月]进行心脏磁共振检查。术后,弓部和降主动脉的血流速度和壁切应力增加(P<0.05);遗传性动脉瘤患者的增加最为显著。总体周向应变与壁切应力相关(r=0.60-0.72,P<0.001);术后降主动脉和胸主动脉段的应变均增加(P<0.001)。移植物引起的远端升主动脉固有段生物力学特性改变与术后降主动脉壁切应力改变相关,证据为移植物导致升主动脉顺应性降低与移植术后远端固有主动脉壁切应力增加之间存在相关性(r=-0.39-0.52;P≤0.05)。

结论

升主动脉人造移植物置换可增加下游主动脉壁切应力和应变。术后降主动脉壁切应力的增加与升主动脉顺应性降低相关,表明移植物提供了高能流和不利的远端主动脉重塑的病灶。