Suppr超能文献

对比增强频谱钼靶摄影中病变强化与乳腺癌的相关性。

Association between lesion enhancement and breast cancer in contrast-enhanced spectral mammography.

机构信息

147011Fatih Sultan Mehmet Training and Research Hospital, Department of Radiology, Istanbul, Turkey.

147011Fatih Sultan Mehmet Training and Research Hospital, Department of General Surgery, Istanbul, Turkey.

出版信息

Acta Radiol. 2023 Jan;64(1):74-79. doi: 10.1177/02841851211060021. Epub 2021 Dec 2.

Abstract

BACKGROUND

Contrast-enhanced spectral mammography (CESM) may help to determine the malignancy potential of lesions according to the degree of enhancement.

PURPOSE

To investigate the correlation between the degree of contrast enhancement of the lesions in contrast-enhanced spectral mammography (CESM) and the final histopathological diagnosis in patients with BI-RADS 4 and 5 lesions.

MATERIAL AND METHODS

CESM was performed in 128 patients who had BI-RADS 4 and 5 lesions on mammography and underwent histopathological examination. A total of 128 index lesions were scored using a 4-point scale regarding the degree of contrast enhancement (0 = no contrast enhancement, 1 = minimal, 2 = moderate, 3 = marked), a score of 2 and 3 was accepted as suggestive of malignancy. The study was approved in our institutional scientific committee.

RESULTS

In total, 76 (59.4%) of the lesions had benign histopathological results, whereas 52 of them had malignant results. Contrast enhancement was not observed in 22.7% of the lesions while 24.2% had minimal enhancement, 18.8% had moderate enhancement, and 34.4% had marked enhancement in CESM. The sensitivity of the degree of contrast enhancement in CESM was 98.1%, when the specificity was 77.6%, positive predictive value was 75%, negative predictive value was 98.3%, and accuracy was 85.9%.

CONCLUSION

This study demonstrated that the degree of contrast enhancement of the lesions in CESM may be used in daily practice with easily performing a visual scale in predicting the malignancy potential of the lesions.

摘要

背景

对比增强光谱乳腺摄影(CESM)可以根据增强程度帮助判断病变的恶性潜能。

目的

探讨对比增强光谱乳腺摄影(CESM)中病变的对比增强程度与 BI-RADS 4 和 5 病变患者最终组织病理学诊断之间的相关性。

材料与方法

对 128 例经乳腺 X 线摄影检查为 BI-RADS 4 和 5 病变并接受组织病理学检查的患者进行 CESM 检查。共对 128 个指数病变进行 4 分制评分,以评估对比增强程度(0 = 无对比增强,1 = 轻微,2 = 中度,3 = 明显),评分 2 和 3 被认为提示恶性。本研究得到了我们机构科学委员会的批准。

结果

总共 76 个(59.4%)病变有良性组织病理学结果,而 52 个有恶性结果。CESM 中 22.7%的病变未见对比增强,24.2%的病变有轻微增强,18.8%的病变有中度增强,34.4%的病变有明显增强。CESM 中病变对比增强程度的灵敏度为 98.1%,特异度为 77.6%,阳性预测值为 75%,阴性预测值为 98.3%,准确性为 85.9%。

结论

本研究表明,CESM 中病变的对比增强程度可用于日常实践中,通过易于执行的视觉量表来预测病变的恶性潜能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验