Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Germany.
Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Germany.
Knee. 2022 Jan;34:1-8. doi: 10.1016/j.knee.2021.11.006. Epub 2021 Dec 3.
The new software, mediCAD® 3D Knee Sport (mediCAD Hectec GmbH, Altdorf/Landshut, Germany), promises to combine automated digital 3D bone model generation, 3D analysis of lower limb geometry including analysis of the patellofemoral joint, and osteotomy planning. The aim of this study was to evaluate its reliability and accuracy.
In this retrospective multi-observer study, three post-mortem CTs were analysed by three observers at three points in time. Reliability was evaluated by calculating the intraclass correlation coefficient (ICC) of interobserver agreement. Accuracy was evaluated using the mean deviation D from the mean and the standard deviation SD from D.
Ten of 18 alignment parameters showed excellent, two good and three moderate interobserver agreement. Poor agreement was found for the mechanical medial proximal tibial angle, the trochlear sulcus angle and trochlea depth. Mean interobserver ICC of all parameters ranged from 0.32 to 0.99. Fifteen of 18 parameters showed a low mean deviation D from the mean of < 2 mm / 2°. Three parameters related to the patellofemoral joint showed medium or high D (patella tilt, trochlear sulcus angle, patellar ridge angle). These parameters also showed the highest values for the SD of D. The trochlear sulcus angle was found to be the only parameter with high mean deviation (D ≥ 5 mm/5°) with D being 5.67 ± 3.23°.
The current version of the software achieves good interobserver reliability and accuracy with the exception of a few measurement parameters.
新软件 mediCAD® 3D Knee Sport(mediCAD Hectec GmbH,德国阿尔特多夫/兰茨胡特)承诺将自动生成数字化 3D 骨骼模型、下肢几何形状的 3D 分析(包括髌股关节分析)和截骨术规划相结合。本研究旨在评估其可靠性和准确性。
在这项回顾性多观察者研究中,三位观察者在三个时间点分析了三具尸体 CT。通过计算观察者间一致性的组内相关系数(ICC)来评估可靠性。使用平均值 D 的平均偏差和 D 的标准偏差 SD 来评估准确性。
10 个对线参数的观察者间一致性为优秀,2 个为良好,3 个为中等。机械性内侧胫骨近端角、滑车沟角和滑车深度的一致性较差。所有参数的观察者间 ICC 均值范围为 0.32 至 0.99。18 个参数中有 15 个平均偏差 D 小于平均值 <2mm/2°。与髌股关节相关的 3 个参数具有中等或高 D(髌骨倾斜度、滑车沟角、髌骨嵴角)。这些参数的 D 的标准差也最高。滑车沟角是唯一具有高平均偏差(D≥5mm/5°)的参数,D 值为 5.67±3.23°。
除了少数测量参数外,该软件当前版本的测量具有良好的观察者间可靠性和准确性。