Knee. 2022 Jan;34:55-61. doi: 10.1016/j.knee.2021.11.005. Epub 2021 Dec 4.
Use of a porous tantalum tibial component for total knee arthroplasty (TKA) was reported to have beneficial effects on periprosthetic bone mineral density (BMD). In some cases, hexagonal peg is placed close to or in contact with the tibial cortex, which may result in stress-shielding around the peg. However, no studies have analyzed the relationship between peg position and BMD. The aim of this study was to compare the peg position and BMD around the peg in a porous tantalum tibial component after TKA.
Twenty-seven patients (27 knees) who underwent primary TKA with a cementless porous tantalum tibial component were investigated. BMD was measured by dual-energy X-ray absorptiometry for 2 years after the operation. The distance between the peg and the tibial cortex (peg distance) was measured on the medial and lateral sides.
BMD was decreased in the medial region after the operation (p < 0.01). Relative change in BMD was lower in the medial region than in the central and lateral regions (p < 0.01). Multiple regression analysis showed that medial peg distance was negatively correlated with relative change of BMD in the medial part of the tibia (p = 0.04, R = 0.402).
The medial peg position affected the postoperative relative change of BMD in the medial part of the tibia, but did not affect the longevity of the implant. As the tibial medial peg became closer to the medial tibial cortex, the BMD loss became larger in the medial part of the tibia at 2 years postoperatively.
在全膝关节置换术(TKA)中使用多孔钽胫骨部件据称对假体周围骨密度(BMD)有有益影响。在某些情况下,六角形销钉靠近或接触胫骨皮质,这可能导致销钉周围的应力屏蔽。然而,尚无研究分析销钉位置与 BMD 之间的关系。本研究旨在比较 TKA 后多孔钽胫骨部件中销钉周围的销钉位置和 BMD。
对 27 例(27 膝)接受非骨水泥多孔钽胫骨部件初次 TKA 的患者进行了研究。术后 2 年内通过双能 X 射线吸收法测量 BMD。测量了内侧和外侧的销钉与胫骨皮质之间的距离(销钉距离)。
术后内侧区域的 BMD 降低(p<0.01)。内侧区域的 BMD 相对变化低于中央和外侧区域(p<0.01)。多元回归分析显示,内侧销钉距离与胫骨内侧部分 BMD 的相对变化呈负相关(p=0.04,R=0.402)。
内侧销钉位置影响胫骨内侧部分术后 BMD 的相对变化,但不影响植入物的寿命。随着胫骨内侧销钉越来越靠近胫骨内侧皮质,术后 2 年内胫骨内侧部分的 BMD 丢失量增大。