Paulter Nicholas G
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA.
J Res Natl Inst Stand Technol. 2017 Sep 19;122:1-14. doi: 10.6028/jres.122.035. eCollection 2017.
Electroshock weapons (ESWs) output a transient burst of impulse-like high-voltage electrical signals that can incapacitate a human target. To ensure safe and effective operation of ESW, their outputs must be accurately measured. Accordingly, the systems used to measure the output of an ESW must be accurately characterized, and their response functions must be known for subsequent processing of the ESW output waveforms (current and high voltage). The long epochs (> 5 s) and high-bandwidth frequency content (> 200 MHz) of the ESW output require unique measurement instrumentation and calibration tools. A frequency-domain swept-frequency method is proposed here for the calibration of the phase response of an ESW measurement system. This method, although motivated by the ESW measurement application, is also applicable to other systems.
电击武器(ESW)输出一阵短暂的类似脉冲的高压电信号,可使人类目标丧失能力。为确保ESW安全有效地运行,必须准确测量其输出。因此,用于测量ESW输出的系统必须得到准确表征,并且必须了解其响应函数,以便随后处理ESW输出波形(电流和高压)。ESW输出的长时间间隔(>5秒)和高带宽频率成分(>200兆赫兹)需要独特的测量仪器和校准工具。本文提出一种频域扫频方法,用于校准ESW测量系统的相位响应。该方法虽然是由ESW测量应用推动的,但也适用于其他系统。