BACKGROUND

The focus of patella maltracking after total knee arthroplasty (TKA) has traditionally been on patella polyethylene damage and failure mechanisms rather than functional outcomes. The purpose of this study was to evaluate the effect of patellar tilt on patient reported outcomes (PROMS) after primary TKA performed with patellar resurfacing.

METHODS

A retrospective review using a single implant design was performed. Patella tilt was radiographically measured according to a standardized protocol. PROMS related to pain, function, and satisfaction were evaluated preoperatively and at minimum 1-year follow-up.

RESULTS

A total of 468 TKAs were included for analysis. Mean age and BMI were 64 years and 35 kg/m; respectively while 63% of patients were female. The median follow-up period was 12.7 months. Overall, patellar tilt was corrected from a median of 5.0 degrees preoperatively to a median of 3.0 degrees postoperatively. Preoperative, postoperative, and the change in patellar tilt had no significant effects on PROMS at minimum 1-year follow-up (p ≥ 0.092). Satisfaction in knee function while getting out of bed was higher for patients with approximately the same patellar tilt before and after TKA compared to patients with an increase in lateral patellar tilt (95% vs 80%, p = 0.025).

CONCLUSIONS

The range of patellar tilt studied in this cohort had little to no effect on PROMS. However, suboptimal patellar tracking may potentiate edge loading of the polyethylene and contribute to implant damage in the long-term. These results are helpful to focus efforts on the tibiofemoral articulation as the predominant determinant of patient outcomes.

摘要

背景

全膝关节置换术后(TKA)髌骨轨迹不良的重点传统上集中在髌骨聚乙烯的损伤和失效机制上,而不是功能结果上。本研究的目的是评估在髌骨表面置换的初次 TKA 后,髌骨倾斜对患者报告的结果(PROMs)的影响。

方法

采用单植入物设计进行回顾性研究。根据标准化方案对髌骨倾斜进行放射学测量。在术前和至少 1 年的随访时,评估与疼痛、功能和满意度相关的 PROMs。

结果

共纳入 468 例 TKA 进行分析。平均年龄和 BMI 分别为 64 岁和 35kg/m2;分别为 63%的患者为女性。中位随访时间为 12.7 个月。总体而言,髌骨倾斜从术前中位数 5.0 度校正至术后中位数 3.0 度。在至少 1 年的随访中,术前、术后和髌骨倾斜的变化对 PROMs 没有显著影响(p≥0.092)。与髌骨外侧倾斜增加的患者相比,TKA 前后髌骨倾斜大致相同的患者在起床时对膝关节功能的满意度更高(95%比 80%,p=0.025)。

结论

在本研究队列中研究的髌骨倾斜范围对 PROMs 几乎没有影响。然而,髌骨跟踪不良可能会加剧聚乙烯的边缘负荷,并导致植入物在长期内损坏。这些结果有助于将重点放在胫骨股骨关节上,因为它是患者结果的主要决定因素。