Ueyanagi Yasushi, Setoyama Daiki, Kawakami Daisuke, Mushimoto Yuichi, Matsumoto Shinya, Hotta Taeko, Kang Dongchon
Department of Clinical Chemistry and Laboratory Medicine, Kyushu University Hospital, Fukuoka 812-8582, Japan.
Department of Clinical Chemistry and Laboratory Medicine, Graduate School of Medical Sciences, Kyushu University, Fukuoka 812-8582, Japan.
Diagnostics (Basel). 2021 Nov 25;11(12):2195. doi: 10.3390/diagnostics11122195.
Gas chromatography-mass spectrometry has been widely used to analyze hundreds of organic acids in urine to provide a diagnostic basis for organic acidemia. However, it is difficult to operate in clinical laboratories on a daily basis due to sample pretreatment processing. Therefore, we aimed to develop a fully automated system for quantifying serum organic acids using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pretreatment CLAM-2030 device was connected to an LC-MS/MS system for processing serum under optimized conditions, which included derivatizing serum organic acids using 3-Nitrophenylhydrazine. The derivatized organic acids were separated on a reverse-phase Sceptor HD-C column and detected using negative-ion electrospray ionization multiple reaction monitoring MS. The automated pretreatment-LC-MS/MS system processed serum in less than 1 h and analyzed 19 serum organic acids, which are used to detect organic acidemias. The system exhibited high quantitative sensitivity ranging from approximately 2 to 100 µM with a measurement reproducibility of 10.4% CV. Moreover, a proof-of-concept validation of the system was performed using sera from patients with propionic acidemia ( = 5), methylmalonic acidemia ( = 2), and 3-methylcrotonylglycinuria ( = 1). The levels of marker organic acids specific to each disease were significantly elevated in the sera of the patients compared to those in control samples. The automated pretreatment-LC-MS/MS system can be used as a rapid in-hospital system to measure organic acid levels in serum for the diagnosis of organic acidemias.
气相色谱 - 质谱联用技术已被广泛用于分析尿液中的数百种有机酸,为有机酸血症提供诊断依据。然而,由于样品预处理过程,该技术在临床实验室中难以每日操作。因此,我们旨在开发一种使用液相色谱 - 串联质谱(LC-MS/MS)定量血清有机酸的全自动系统。预处理CLAM - 2030装置连接到LC-MS/MS系统,在优化条件下处理血清,其中包括使用3-硝基苯肼衍生化血清有机酸。衍生化的有机酸在反相Sceptor HD-C柱上分离,并使用负离子电喷雾电离多反应监测质谱进行检测。该全自动预处理 - LC-MS/MS系统在不到1小时内处理血清,并分析19种血清有机酸,这些有机酸用于检测有机酸血症。该系统表现出高定量灵敏度,范围约为2至100μM,测量重现性为10.4%CV。此外,使用丙酸血症患者(n = 5)、甲基丙二酸血症患者(n = 2)和3-甲基巴豆酰甘氨酸尿症患者(n = 1)的血清对该系统进行了概念验证。与对照样品相比,各疾病特异性标记有机酸在患者血清中的水平显著升高。该全自动预处理 - LC-MS/MS系统可作为医院内快速系统,用于测量血清中的有机酸水平以诊断有机酸血症。