高频三维管腔容积超声是检测弹性蛋白酶诱导的小鼠腹主动脉瘤早期动脉瘤变化的灵敏方法。

High-Frequency Three-Dimensional Lumen Volume Ultrasound Is a Sensitive Method to Detect Early Aneurysmal Change in Elastase-Induced Murine Abdominal Aortic Aneurysm.

作者信息

Waduud Mohammed A, Kandavelu Parkavi, Reay Melanie, Paradine Katherine, Scott David J A, Bailey Marc A

机构信息

Leeds Institute for Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, United Kingdom.

Leeds Vascular Institute, Leeds General Infirmary, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.

出版信息

Aorta (Stamford). 2021 Dec;9(6):215-220. doi: 10.1055/s-0041-1731404. Epub 2021 Dec 28.

Abstract

OBJECTIVE

The aim of this study was to investigate the reproducibility of anterior-posterior diameter (APd) and three-dimensional lumen volume (3DLV) measurements of abdominal aortic aneurysms (AAA) in a classical murine AAA model. We also compared the magnitude of change in the aortic size detected with each method of assessment.

METHODS

Periadventitial application of porcine pancreatic elastase (PPE AAA) or sham surgery was performed in two cohorts of mice. Cohort 1 was used to assess for observer variability with the APd and 3DLV measurements. Cohort 2 highlighted the relationship between APd and 3DLV and changes in AAA detected.

RESULTS

There was no significant observer variability detected with APd measurement. Similarly, no significant intraobserver variability was evident with 3DLV; however, a small but significant interobserver difference was present. APd and 3DLV measurements of PPE AAA significantly correlated. However, changes in the AAA morphology were detected earlier with 3DLV.

CONCLUSION

APd and 3DLV are both reliable methods for measuring an AAA. Both these methods correlate with each other. However, changes in AAA morphology were detected earlier with 3DLV, which is important to detect subtle but important changes to aortic geometry in a laboratory setting. 3DLV measurement of AAA is a simple, reproducible, and comprehensive method for assessing changes in disease morphology.

摘要

目的

本研究旨在探讨在经典小鼠腹主动脉瘤(AAA)模型中,腹主动脉瘤前后径(APd)和三维管腔容积(3DLV)测量的可重复性。我们还比较了每种评估方法检测到的主动脉大小变化幅度。

方法

在两组小鼠中进行猪胰弹性蛋白酶外膜周围应用(PPE AAA)或假手术。队列1用于评估APd和3DLV测量的观察者变异性。队列2突出了APd与3DLV之间的关系以及检测到的AAA变化。

结果

APd测量未检测到显著的观察者变异性。同样,3DLV也没有明显的观察者内变异性;然而,存在微小但显著的观察者间差异。PPE AAA的APd和3DLV测量显著相关。然而,3DLV更早检测到AAA形态的变化。

结论

APd和3DLV都是测量AAA的可靠方法。这两种方法相互关联。然而,3DLV更早检测到AAA形态的变化,这对于在实验室环境中检测主动脉几何形状的细微但重要的变化很重要。AAA的3DLV测量是一种简单、可重复且全面的评估疾病形态变化的方法。