Suppr超能文献

碘代苯丙胺脑血流评估的γ射线有效性(REICA)方法用于定量评估包括乙酰唑胺挑战试验在内的脑血流。

Validity of the γ-Ray Evaluation with iodoamphetamine for Cerebral Blood Flow Assessment (REICA) method for quantification of cerebral blood flow including acetazolamide challenge test.

机构信息

Department of Radiology, National Hospital Organization Kyushu Medical Center, 1-8-1, Jigyohama, Chuo-Ku, Fukuoka-City, Fukuoka, 810-8563, Japan.

Department of Radiological Technology, Radiological Diagnosis, National Cancer Center, 5-1-1, Tsukiji, Chuo-Ku, Tokyo, 104-0045, Japan.

出版信息

Ann Nucl Med. 2022 Mar;36(3):279-284. doi: 10.1007/s12149-021-01700-w. Epub 2022 Jan 1.

Abstract

OBJECTIVE

The γ-Ray Evaluation with iodoamphetamine for Cerebral Blood Flow Assessment (REICA) is a new method for quantifying cerebral blood flow (CBF) using single-photon emission computed tomography (SPECT) and [I]N-isopropyl-p-iodoamphetamine (I-IMP). The present study aimed to validate the REICA method using data including acetazolamide challenge test.

METHODS

The REICA and Graph-Plot (GP) methods were used to calculate mean CBF (mCBF) for 92 acquisitions (rest: 57, stress: 35) and cerebrovascular reactivity (CVR) in 33 patients. To obtain stress data, 15 mg/kg of acetazolamide was injected intravenously 10 min before the administration of I-IMP, and blood samples were collected under the same conditions as rest data. The reference standard was the Autoradiograph (ARG) method using arterial blood sampling, and the accuracy of the REICA method was analyzed by comparing it with each method.

RESULTS

For mCBF, the correlation coefficients (r) were 0.792 for the REICA method and 0.636 for the GP method. For CVR, r values were 0.660 for the REICA method and 0.578 for the GP method. In both acquisitions, the REICA method had a stronger correlation with the ARG method than the GP method. For mCBF, there was a significant difference in the correlation coefficient between the two correlation coefficients (p < 0.01).

CONCLUSIONS

The REICA method was more accurate than the GP method in quantifying CBF and closer to the ARG method. The REICA method, which is a noninvasive method of cerebral blood flow quantification using I-IMP, has great medical usefulness.

摘要

目的

使用单光子发射计算机断层扫描(SPECT)和[I]N-异丙基-p-碘安非他命(I-IMP)评估γ-射线评估碘安非他命的脑血流(CBF)(REICA)是一种定量脑血流(CBF)的新方法。本研究旨在使用包括乙酰唑胺挑战试验的数据验证 REICA 方法。

方法

使用 REICA 和 Graph-Plot(GP)方法计算 33 例患者的 92 次采集(休息:57 次,应激:35 次)和脑血管反应性(CVR)的平均 CBF(mCBF)。为了获得应激数据,在给予 I-IMP 前 10 分钟静脉注射 15mg/kg 乙酰唑胺,并在与休息数据相同的条件下采集血样。参考标准是使用动脉采血的 Autoradiograph(ARG)方法,通过与每种方法进行比较来分析 REICA 方法的准确性。

结果

对于 mCBF,REICA 方法的相关系数(r)为 0.792,GP 方法为 0.636。对于 CVR,REICA 方法的 r 值为 0.660,GP 方法为 0.578。在两种采集方式中,REICA 方法与 ARG 方法的相关性均强于 GP 方法。对于 mCBF,两种相关系数之间的相关系数存在显著差异(p<0.01)。

结论

REICA 方法在定量 CBF 方面比 GP 方法更准确,并且更接近 ARG 方法。REICA 方法是一种使用 I-IMP 进行无创脑血流定量的方法,具有很大的医学用途。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f805/8897379/d7bd7b141562/12149_2021_1700_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验