Kirschfink M, Borsos T
Mol Immunol. 1987 Mar;24(3):253-7. doi: 10.1016/0161-5890(87)90143-x.
IgG anti-cell antibodies are inefficient in inducing cell lysis by complement. C mediated lysis by anti-cell IgG can be augmented by the use of C fixing anti-antibody. We have studied augmentation of rabbit anti-Forssman IgG, rabbit anti-methotrexate IgG and rabbit anti-folinic acid IgG antibodies by rabbit anti-allotype IgG antibodies. Large variability (from a low of 2 to a high of over 100) was found in augmentation efficiency even with the same anti-allotype antibody; the variability was primarily the function of the anti-hapten antibody. It was concluded that quantitative studies on anti-hapten IgG production relying on augmented hemolysis may lead to misleading conclusions.