Suppr超能文献

技术报告:使用加热诊断检眼镜镜片减少与患者面罩佩戴相关的镜片起雾。

Technical Report: Reducing Lens Fogging Associated with Patient Mask Wearing with Heated Diagnostic Fundoscopy Lenses.

出版信息

Optom Vis Sci. 2022 Apr 1;99(4):389-393. doi: 10.1097/OPX.0000000000001863.

Abstract

SIGNIFICANCE

Severe acute respiratory syndrome coronavirus 2 has indirectly created challenges to the ophthalmic retinal examinations because of lens fogging related to patients wearing masks. To date, there are no objective data on the degree of diagnostic ophthalmic lens fogging associated with mask wearing or on the effectiveness of proposed solutions to ophthalmologic lens fogging.

PURPOSE

The purposes of this study were to investigate the degree of ophthalmologic lens fogging in patients wearing masks and to assess the efficacy lens warming in reducing lens fogging and facilitating ophthalmologic retinal examinations.

METHODS

This study quantified the degree of lens fogging in mask-wearing subjects using ImageJ to measure lens surface area fogged in slit-lamp photographs of 90 D lenses before and after the use of a lens warmer. We investigated the clinical relevance of diagnostic lens fogging via a survey study of eye care providers. Subjects rated on a Likert scale their experience with diagnostic lens fogging during retinal examination in mask-wearing patients with and without the use of a lens warming device.

RESULTS

For mask-wearing subjects, the percentage of fogged lens area in a 90 D lens averaged 32.5% using an unheated lens and 1.1% using a heated lens. Survey responders noted significantly less fogging of the 78 and 90 D lenses on retinal examination when using the lens warmer (P < .001) and found that using the lens warmer facilitated their retinal examination (P < .001).

CONCLUSIONS

This study shows that there is significant fogging of ophthalmic slit-lamp lenses associated with patients wearing masks and that using a lens warmer significantly reduces fogging and facilitates retinal examinations. Eye care providers would benefit from the use of a lens warmer to reduce diagnostic lens fogging during retinal examination.

摘要

意义

由于与患者佩戴口罩相关的镜片起雾,严重急性呼吸综合征冠状病毒 2 间接对眼科视网膜检查造成了挑战。迄今为止,尚无关于与佩戴口罩相关的眼科镜片起雾程度的客观数据,也没有关于提出的解决眼科镜片起雾方法的有效性的数据。

目的

本研究旨在调查佩戴口罩患者的眼科镜片起雾程度,并评估镜片加热在减少镜片起雾和促进眼科视网膜检查方面的效果。

方法

本研究使用 ImageJ 量化了佩戴口罩患者的镜片起雾程度,通过测量 90D 镜片在使用镜片加热装置前后的裂隙灯照片中的镜片表面起雾面积来实现。我们通过对眼科护理提供者的调查研究来研究诊断性镜片起雾的临床相关性。研究对象使用李克特量表对佩戴口罩患者在进行视网膜检查时使用和不使用镜片加热装置时的诊断性镜片起雾体验进行评分。

结果

对于佩戴口罩的受试者,未加热镜片的 90D 镜片的平均起雾镜片面积百分比为 32.5%,而加热镜片的平均起雾镜片面积百分比为 1.1%。调查应答者指出,在使用镜片加热装置时,78 和 90D 镜片在视网膜检查时的起雾明显减少(P<.001),并且发现使用镜片加热装置使他们的视网膜检查更加方便(P<.001)。

结论

本研究表明,患者佩戴口罩会导致眼科裂隙灯镜片严重起雾,而使用镜片加热装置可显著减少起雾并使视网膜检查更加方便。镜片加热装置有助于减少视网膜检查中的诊断性镜片起雾,这将使眼科护理提供者受益。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验