Suppr超能文献

乙二胺四乙酸(EDTA)对犬促肾上腺皮质激素(ACTH)、皮质醇和甲状腺激素化学发光免疫分析测定的影响。

Effects of EDTA on chemiluminescent immunoassay measurement of ACTH, cortisol, and thyroid hormones in dogs.

作者信息

Hirsch A L, Fletcher J M, Mitchell M A

机构信息

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, Louisiana, 70803, USA.

Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, Louisiana, 70803, USA; Louisiana Animal Disease Diagnostic Laboratory, Louisiana State University, Baton Rouge, Louisiana 70803, USA.

出版信息

Domest Anim Endocrinol. 2022 Apr;79:106707. doi: 10.1016/j.domaniend.2021.106707. Epub 2021 Dec 14.

Abstract

When measuring blood hormones, pre-analytical sample handling can impact the quality of the results. Previous studies have shown improved stability of canine cortisol in ethylenediaminetetraacetic acid (EDTA) plasma compared to serum and interchangeability of serum and plasma when cortisol is measured by radioimmunoassay. Additionally, cortisol samples were also interchangeable when measured by chemiluminescent immunoassay if the EDTA concentration was consistent with that of optimally filled tubes, whereas excess EDTA interfered with the measurement of cortisol and serum and EDTA plasma were not interchangeable when measuring total thyroxine (TT4). The main limitation of these studies was that they were performed by spiking pooled serum samples with EDTA or in previously collected blood samples submitted to a clinical pathology laboratory. The purpose of the present study was to evaluate the effect of EDTA on the measurement of adrenocorticotropic hormone (ACTH), cortisol, TT4, free thyroxine (FT4), and thyroid stimulating hormone (TSH) in healthy dogs using the Siemens IMMULITE 1000. Whole blood from forty dogs was aliquoted into three Monoject sample tubes: no additive, completely filled EDTA tube, and 50% filled EDTA tube. Handling and storage conditions were identical, and all samples were analyzed on the same day. Bland-Altman plots and Passing-Bablok regression were used to assess agreement and risks for error, respectively. Proportional errors were found between serum and plasma samples for ACTH, cortisol, TT4, FT4, and TSH; systematic errors were also found for FT4. There was poor agreement and clinically significant differences between the measured concentrations of all hormones in serum and plasma, proving that these sample types are not interchangeable. Incompletely filled EDTA tubes were associated with significantly lower ACTH concentrations compared to completely filled EDTA tubes. When measured by chemiluminescent immunoassays that utilize alkaline phosphatase at the reporter enzyme, serum should be used for cortisol, TT4, FT4, and TSH, while plasma from completely filled EDTA tubes should be used for ACTH.

摘要

在测量血液激素时,分析前的样本处理会影响结果的质量。先前的研究表明,与血清相比,犬类皮质醇在乙二胺四乙酸(EDTA)血浆中的稳定性有所提高,并且当通过放射免疫测定法测量皮质醇时,血清和血浆具有互换性。此外,如果EDTA浓度与最佳填充管的浓度一致,那么通过化学发光免疫测定法测量时,皮质醇样本也具有互换性;然而,过量的EDTA会干扰皮质醇的测量,并且在测量总甲状腺素(TT4)时,血清和EDTA血浆不可互换。这些研究的主要局限性在于,它们是通过向混合血清样本中添加EDTA或在提交给临床病理实验室的先前采集的血液样本中进行的。本研究的目的是使用西门子IMMULITE 1000评估EDTA对健康犬促肾上腺皮质激素(ACTH)、皮质醇、TT4、游离甲状腺素(FT4)和促甲状腺激素(TSH)测量的影响。将40只犬的全血分装到三个莫诺杰特样本管中:无添加剂管、完全填充EDTA管和50%填充EDTA管。处理和储存条件相同,所有样本均在同一天进行分析。采用布兰德-奥特曼图和帕辛-巴布洛赫回归分别评估一致性和误差风险。在ACTH、皮质醇、TT4、FT4和TSH的血清和血浆样本之间发现了比例误差;在FT4方面也发现了系统误差。血清和血浆中所有激素的测量浓度之间一致性较差且存在临床显著差异,证明这些样本类型不可互换。与完全填充EDTA管相比,未完全填充的EDTA管与显著更低的ACTH浓度相关。当通过在报告酶处使用碱性磷酸酶的化学发光免疫测定法进行测量时,皮质醇、TT4、FT4和TSH应使用血清,而ACTH应使用完全填充EDTA管中的血浆。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验