Department of Radiation Oncology, Tung's Taichung Metroharbor Hospital, Taichung, Taiwan.
Department of Radiation Oncology, Nantou Hospital, Ministry of Health and Welfare, Nantou, Taiwan.
Technol Health Care. 2022;30(S1):329-336. doi: 10.3233/THC-THC228031.
The routine radiation therapy treatment planning does not include secondary radiation and peripheral doses resulting from radiotherapy exposure in patients with nasopharyngeal carcinoma (NPC) undergoing Volumetric Modulated Arc Therapy (VMAT) using an linear accelerator (linac) of Axesse (Elekta 2538).
VMAT has a better dose conformity of the tumor and is also operated by adjusting the shapes of mulileaf collimator. However, such treatment is potentially important to improve the accuracy of estimated health risks.
This study aimed to evaluate the equivalent dose of organ or tissue (DT) and effective dose (E) for normal organs using the Alderson Rando phantom as an equivalent of the human body. Thermoluminescent dosimeters (TLD-100H) were calibrated by 6 MV X-ray originated by the linac. A total of 252 TLDs were used. These TLDs were inserted into phantom organ or tissue which closely approximated to these places.
The thyroid dose (D𝑡ℎ𝑦) had the highest dose, 1840 ± 202 mSv/treatment. The E of the Rando was 7.11 ± 0.61 mSv/treatment, as estimated using ICRP 103. The skin doses (D𝑠𝑘𝑖𝑛) varied significantly outside the treatment field and decreased as the distance from the treatment field increased.
This study can be referred to practical guidance regarding radiation protections of the public.
常规放射治疗计划不包括因鼻咽癌(NPC)患者接受容积调强弧形治疗(VMAT)而导致的二次辐射和外周剂量,该治疗使用 Axesse(Elekta 2538)线性加速器(linac)。
VMAT 具有更好的肿瘤适形性,还可以通过调整多叶准直器的形状进行操作。然而,这种治疗对于提高估计健康风险的准确性可能非常重要。
本研究旨在使用 Alderson Rando 体模作为人体等效物,评估器官或组织的当量剂量(DT)和有效剂量(E)。Thermoluminescent dosimeters(TLD-100H)通过来自 linac 的 6 MV X 射线进行校准。总共使用了 252 个 TLD。这些 TLD 被插入到与这些部位非常接近的体模器官或组织中。
甲状腺剂量(D𝑡ℎ𝑦)最高,每次治疗为 1840 ± 202 mSv。使用 ICRP 103 估计,Rando 的 E 为 7.11 ± 0.61 mSv/治疗。皮肤剂量(D𝑠𝑘𝑖𝑛)在治疗场外变化显著,并随着与治疗场距离的增加而减小。
本研究可为公众的辐射防护提供实际指导。