Suppr超能文献

3D SPACE FLAIR 与 3D TSE FLAIR 在梅尼埃病中的对比。

Comparison between 3D SPACE FLAIR and 3D TSE FLAIR in Menière's disease.

机构信息

Department of Radiology, GZA Hospitals Antwerp, Oosterveldlaan 24, 2610, Antwerp, Belgium.

Lab for Equilibrium Investigations and Aerospace, University of Antwerp, Universiteitsplein 1, 2610, Antwerp, Belgium.

出版信息

Neuroradiology. 2022 May;64(5):1011-1020. doi: 10.1007/s00234-022-02913-0. Epub 2022 Feb 12.

Abstract

PURPOSE

Heavily T2-weighted 3D FLAIR (hTw-3D-FLAIR) sequence with constant flip angle (CFA) has been reported as being more sensitive to low concentrations of gadolinium (Gd) enabling endolymphatic hydrops (EH) visualization. The purpose of this study was to compare signal-to-noise (SNR) ratio, detection rate of EH, and increased perilymphatic enhancement (PE) as well as diagnostic accuracy in diagnosing definite Menière's disease (MD), using 3D-SPACE FLAIR versus conventional 3D-TSE FLAIR.

METHODS

This retrospective study included 29 definite MD patients who underwent a 4-h delayed intravenous (IV) Gd-enhanced 3D-TSE FLAIR and 3D-SPACE FLAIR MRI between February 2019 and February 2020. MR images were qualitatively and quantitatively analyzed twice by 2 experienced head and neck radiologists. Qualitative assessment included grading of cochlear and vestibular EH and visual comparison of PE. Quantitative assessment of PE was performed by placing a region of interest (ROI) and ratio calculation in the basal turn of the cochlea and the brainstem.

RESULTS

The intra- and inter-reader reliability for grading of EH and PE was excellent (0.7 < kappa < 0.9) for 3D-SPACE FLAIR and exceeded the values for 3D-TSE FLAIR (0.5 < kappa < 0.9) The combination of EH and visual assessment of PE has the highest diagnostic accuracy in diagnosing definite MD on 3D-SPACE FLAIR with a sensitivity of 0.91 and a specificity of 0.98 resulting in a sensitivity raise of 6% compared to 3D-TSE FLAIR.

CONCLUSION

Four-hour delayed IV Gd-enhanced 3D-SPACE FLAIR sequence has a higher sensitivity and reproducibility than 3D-TSE FLAIR for the visualization of EH and increased PE in definite MD patients.

摘要

目的

具有恒定翻转角(CFA)的重度 T2 加权 3D FLAIR(hTw-3D-FLAIR)序列已被报道对低浓度钆(Gd)更敏感,能够可视化内淋巴积水(EH)。本研究的目的是比较使用 3D-SPACE FLAIR 与常规 3D-TSE FLAIR 时,信号噪声比(SNR)、EH 的检出率、增加的外淋巴增强(PE)以及诊断明确梅尼埃病(MD)的诊断准确性。

方法

本回顾性研究纳入了 29 例明确 MD 患者,他们在 2019 年 2 月至 2020 年 2 月期间接受了 4 小时延迟静脉(IV)Gd 增强 3D-TSE FLAIR 和 3D-SPACE FLAIR MRI。由 2 名经验丰富的头颈部放射科医生对 MR 图像进行定性和定量分析。定性评估包括耳蜗和前庭 EH 的分级以及 PE 的视觉比较。通过在耳蜗基底转和脑干上放置感兴趣区域(ROI)并进行比值计算,对 PE 进行定量评估。

结果

3D-SPACE FLAIR 对 EH 和 PE 分级的读者内和读者间可靠性为优(0.7<kappa<0.9),超过了 3D-TSE FLAIR 的值(0.5<kappa<0.9)。EH 分级和 PE 的视觉评估相结合,3D-SPACE FLAIR 诊断明确 MD 的诊断准确性最高,敏感性为 0.91,特异性为 0.98,与 3D-TSE FLAIR 相比,敏感性提高了 6%。

结论

与 3D-TSE FLAIR 相比,4 小时延迟 IV Gd 增强 3D-SPACE FLAIR 序列在明确 MD 患者中对 EH 和增加的 PE 的可视化具有更高的敏感性和可重复性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/95a8/9005391/677c3ac60227/234_2022_2913_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验