Traditional approaches to cervical vestibular-evoked myogenic potentials use a transient stimulus to elicit an onset response. However, alternate approaches with long duration stimuli may allow the development of new methodologies to better understand basic function of the vestibular system, as well as potentially developing new clinical applications.
The objective of this study was to examine the effects of stimulus polarity on response properties of amplitude-modulated cervical vestibular-evoked myogenic potentials (AMcVEMPs).
Prospective, repeated-measures, within-subjects design.
Participants were 16 young, healthy adults (ages 21-38 years).
Amplitude-modulated tones, with carrier frequency of 500 Hz and modulation frequency of 37 Hz, were used to elicit AMcVEMPs. Responses were analyzed in three different stimulus polarity conditions: condensation, rarefaction, and alternating. The resulting data were analyzed for differences across polarity conditions.
AMcVEMP amplitudes, both raw and corrected for tonic muscle activation, were equivalent across the different stimulus phase conditions. In addition, response signal-to-noise ratio and phase coherence were equivalent across the different phases of the stimulus.
Analyses of AMcVEMPs are stable when the carrier frequency starting phase is altered and the phase of the temporal envelope is constant.
传统的颈前庭诱发肌源性电位(cervical vestibular-evoked myogenic potentials,cVEMPs)方法采用短暂刺激来引出起始反应。然而,使用长时程刺激的替代方法可能会开发出新的方法来更好地理解前庭系统的基本功能,并可能开发出新的临床应用。
本研究的目的是探讨刺激极性对调制颈前庭诱发肌源性电位(amplitude-modulated cervical vestibular-evoked myogenic potentials,AMcVEMPs)反应特性的影响。
前瞻性、重复测量、自身对照设计。
参与者为 16 名年轻健康的成年人(年龄 21-38 岁)。
采用载波频率为 500 Hz、调制频率为 37 Hz 的调制声刺激来引出 AMcVEMPs。在三种不同的刺激极性条件下(压缩、稀疏和交替)分析反应。分析数据在不同极性条件下的差异。
未经和经紧张性肌肉激活校正后的 AMcVEMP 幅度在不同刺激相位条件下是等效的。此外,刺激不同相位的反应信号噪声比和相位相干性是等效的。
当载波频率起始相位改变而时间包络的相位恒定时,AMcVEMPs 的分析是稳定的。