Suppr超能文献

吻合静脉血流连接器在头颈部游离皮瓣重建中的结果-单中心五年经验。

Outcomes of anastomotic venous flow couplers in head and neck free flap reconstruction - five-year experience in a single centre.

机构信息

Department of Oral & Maxillofacial Surgery, Leeds Teaching Hospital NHS Trust, Leeds Dental Institute, Clarendon Way, Leeds LS2 9LU, West Yorkshire, United Kingdom.

Department of Oral & Maxillofacial Surgery, Leeds Teaching Hospital NHS Trust, Leeds Dental Institute, Clarendon Way, Leeds LS2 9LU, West Yorkshire, United Kingdom.

出版信息

Br J Oral Maxillofac Surg. 2022 Jul;60(6):847-851. doi: 10.1016/j.bjoms.2022.01.002. Epub 2022 Jan 12.

Abstract

Flow couplers for venous anastomosis, which enable the invasive monitoring of free flaps during the postoperative period with a continuous venous signal audible immediately after completion of the anastomosis, have been reported to be reliable, sensitive, and specific as anastomotic flap monitoring adjuncts. The purpose of this study was to evaluate the reliability, sensitivity, specificity, and outcomes of surgical exploration, and the impact on free-flap survival of the venous anastomotic flow coupler for microvascular head and neck reconstruction in a consecutive series of patients. This is a retrospective review of consecutive patients treated in the department of oral and maxillofacial surgery who underwent reconstruction of a head and neck defect using venous anastomosis with a flow coupler-vascularised free flap between October 2015 and December 2020. A total of 189 patients had free-flap reconstruction of head and neck defects. We compared the venous flow coupler group (n = 72) with patients who had free flaps with hand-sewn anastomoses over the same period (n = 117). There were no false positive/negatives associated with the flow coupler as an implantable flap monitor. The flow coupler cohort had a significantly higher flap salvage rate compared with free flaps that were monitored clinically (p = 0.04). The venous flow coupler has been shown to be a reliable microvascular anastomotic and invasive flap monitor that enables accurate and timely detection of flap compromise and prompt, successful free-flap salvage.

摘要

用于静脉吻合的流量耦合器可在术后期间通过连续的静脉信号进行有创监测,完成吻合后即可立即听到,被认为是可靠、敏感和特异的吻合瓣监测辅助工具。本研究旨在评估连续系列患者中,用于微血管头颈部重建的静脉吻合流量耦合器的可靠性、敏感性、特异性和手术探查结果,以及对游离皮瓣存活的影响。这是对 2015 年 10 月至 2020 年 12 月期间在口腔颌面外科接受治疗的连续患者进行的回顾性研究,这些患者采用带有流量耦合器的静脉吻合进行头颈部缺损的游离皮瓣重建。共有 189 例患者进行了头颈部缺陷的游离皮瓣重建。我们将静脉流量耦合器组(n = 72)与同期接受手工吻合游离皮瓣的患者(n = 117)进行了比较。流量耦合器作为一种可植入皮瓣监测器,没有假阳性/假阴性。与临床监测的游离皮瓣相比,流量耦合器组的皮瓣存活率显著更高(p = 0.04)。静脉流量耦合器已被证明是一种可靠的微血管吻合和有创皮瓣监测器,可准确及时地检测皮瓣受损,并及时成功地挽救游离皮瓣。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验