在接受镫骨切除术的患者中,移除并重新定位因创伤而进入前庭的活塞式钢丝假体。

Removal and Repositioning of a Piston Wire Prosthesis That Entered the Vestibule Secondary to Trauma in a Patient Who Underwent Stapedotomy.

作者信息

Koh Sung Min, Kim Younghac, Park Joo Hyun, Cho Young Sang

机构信息

Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

出版信息

J Audiol Otol. 2022 Oct;26(4):223-226. doi: 10.7874/jao.2021.00626. Epub 2022 Feb 24.

Abstract

Otosclerosis is a common cause of adult-onset hearing impairment, and stapedotomy is often performed as surgical treatment. Several studies have reported the complications of stapedotomy surgery; piston wire prosthesis (PWP) disruption or dislocation secondary to indirect force attributable to head trauma is described in many patients. Most PWPs that get displaced are slanted or are completely dislodged from the stapedotomy site and lodged within the middle ear. PWP dislocation into the vestibule is extremely rare. A 65-year-old woman who was involved in a traffic accident underwent computed tomography, which revealed a right-sided PWP in the vestibule. Two weeks after the accident, we observed conductive hearing loss associated with a large air-bone gap (ABG, 47 dB) accompanied by spontaneous nystagmus directed to the right without any change in nystagmus following changes in head or body position. She underwent endoscopic exploratory tympanotomy under general anesthesia, 23 days after the injury. We gently pulled the PWP from the vestibule and repositioned it at its original site with a length of 5.2 mm on the long process of the incus. Pure tone audiometry performed 8 months postoperatively showed a decrease in the ABG from 47 to 10 dB without any complications.

摘要

耳硬化症是成人听力障碍的常见病因,镫骨切除术常作为手术治疗方法。多项研究报告了镫骨切除术的并发症;许多患者描述了因头部外伤间接作用力导致的活塞钢丝假体(PWP)断裂或脱位。大多数移位的PWP呈倾斜状或从镫骨切除部位完全脱出并滞留在中耳内。PWP脱位进入前庭极为罕见。一名65岁女性在交通事故后接受了计算机断层扫描,结果显示前庭内有一个右侧PWP。事故发生两周后,我们观察到传导性听力损失,伴有较大的气骨导间距(ABG,47dB),伴有自发的向右眼震,头部或身体位置改变后眼震无任何变化。受伤23天后,她在全身麻醉下接受了内镜探查性鼓室切开术。我们从前庭轻轻拉出PWP,并将其重新放置在砧骨长突上原来的位置,长度为5.2mm。术后8个月进行的纯音听力测试显示ABG从47dB降至10dB,无任何并发症。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/de5d/9597272/7ddd9b2636a6/jao-2021-00626f1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验