Suppr超能文献

九柱戏测试在单侧痉挛性脑瘫患者中的可靠性和一致性。

Reliability and agreement of the Nine Hole Peg Test in patients with unilateral spastic cerebral palsy.

机构信息

ASPACE (Asociación de Personas Con Parálisis Cerebral) Extremadura, Cáceres, Spain.

Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, Madrid, Spain.

出版信息

Eur J Pediatr. 2022 Jun;181(6):2283-2290. doi: 10.1007/s00431-022-04423-w. Epub 2022 Feb 25.

Abstract

Upper extremity involvement is one of the most common motor impairments in children with unilateral spastic cerebral palsy (CP). One tool for the assessment of manual function in CP is the Nine Hole Peg Test (NHPT). However, the reliability of the NHPT in patients with unilateral CP is unknown. This study aimed to analyze the intra-rater inter-session reliability of the NHPT in unilateral spastic CP, for its use in clinical practice and research. A total of 27 participants with spastic unilateral CP were included. Reliability was verified by the intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change. The agreement was analyzed by the Bland-Altman method. An excellent intra-rater reliability was observed for the non-affected side (ICC = 0.94) and the affected side (ICC = 0.96). The minimal detectable change was 4 and 12 s for the non-affected and affected side, respectively. There were no significant biases between repetitions.   Conclusions: The NHPT showed excellent intra-rater inter-session reliability in patients with spastic unilateral CP. In addition, the test shows adequate agreement and proportionally small errors to assess manual dexterity. What is Known: • The Nine Hole Peg Test (NHPT) is widely used to assess dexterity in patients with neurological conditions. • The NHPT has demonstrated appropriate measurement properties in healthy children and adults with neurological conditions. What is New: • The NHPT presents excellent reliability, small measurement errors, and adequate agreement for the assessment of patients with cerebral palsy. • The measurement error of the NHPT in unilateral cerebral palsy may be up to 13% of the total time to perform it.

摘要

上肢功能障碍是单侧痉挛性脑瘫(CP)患儿最常见的运动障碍之一。评估 CP 患者手功能的工具之一是九孔插钉测试(NHPT)。然而,单侧 CP 患者的 NHPT 可靠性尚不清楚。本研究旨在分析 NHPT 在单侧痉挛性 CP 中的测试-重测内评估者可靠性,以便在临床实践和研究中使用。共纳入 27 例痉挛性单侧 CP 患者。通过组内相关系数(ICC)、测量误差和最小可检测变化来验证可靠性。通过 Bland-Altman 方法分析一致性。非患侧(ICC=0.94)和患侧(ICC=0.96)的内评估者可靠性极好。非患侧和患侧的最小可检测变化分别为 4s 和 12s。重复之间没有明显的偏差。结论:NHPT 在痉挛性单侧 CP 患者中具有极好的内评估者测试-重测可靠性。此外,该测试具有足够的一致性和相对较小的误差,可用于评估手的灵巧度。已知:•九孔插钉测试(NHPT)广泛用于评估神经疾病患者的灵巧度。•NHPT 已在神经疾病的健康儿童和成人中表现出适当的测量特性。新内容:•NHPT 对脑瘫患者的评估具有极好的可靠性、较小的测量误差和足够的一致性。•NHPT 在单侧脑瘫中的测量误差可能高达总测试时间的 13%。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8409/8873351/50635fbe5ded/431_2022_4423_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验