Department of Haematology, Singapore General Hospital, Singapore.
Department of Pharmacy, Singapore General Hospital, Singapore.
Hematology. 2022 Dec;27(1):337-342. doi: 10.1080/16078454.2022.2043573.
Thrombin generation assays and activated partial thromboplastin time (aPTT)-based clot waveform analysis (CWA), are some examples of global coagulation assays. Each modality evaluates different aspects of the clot forming process to globally define haemostasis with exclusive measurement parameters. Data on CWA are emerging, but its performance against other haemostatic assays is yet to be ascertained. This study evaluates the correlation between aPTT-based CWA and CAT parameters across a range of INR in warfarin-treated patients.
PATIENTS/METHODS: A prospective study consisting of patients on warfarin anticoagulation with varying INR levels. CWA and CAT were performed for the study subjects.
54 samples were included covering an INR range from 1.33-6.89, with a mean of 4.31 +/- 1.13. For CAT parameters, endogenous thrombin potential (ETP) and peak thrombin were assessed. Both unadjusted and adjusted (adjusted for final plateau transmittance) aPTT-based CWA were evaluated for parameters min1 (maximum velocity), min2 (maximum acceleration) and max2 (maximum deceleration). Peak thrombin showed significant correlation with all CWA parameters (min1: r = 0.435, <0.001; min2: r = 0.485, <0.001; max2: r = 0.578, <0.001; adjusted min1: r = 0.734, <0.001, adjusted min2: r = 0.693, <0.001; adjusted max2: r = 0.751, <0.001). ETP correlated significantly with all CWA parameters except unadjusted min1 (min1: r = 0.235, = 0.087; min2: r = 0.326, = 0.016; max2: r = 0.437, <0.001; adjusted min1: r = 0.610, <0.001, adjusted min2: r = 0.563, <0.001; adjusted max2: r = 0.642, <0.001).
We demonstrated a modest correlation between CAT and CWA parameters. Adjusted CWA improved this correlation. These findings provide additional understanding of CWA and it's role in the evaluation of global haemostatic function.
凝血酶生成试验和基于活化部分凝血活酶时间(aPTT)的凝块波形分析(CWA)是一些评估整体凝血的方法。每种方法都评估血栓形成过程的不同方面,通过独特的测量参数来全面定义止血。关于 CWA 的数据正在不断涌现,但它在其他止血检测中的性能仍有待确定。本研究评估了在华法林治疗的患者中,基于 aPTT 的 CWA 与 CAT 参数在不同 INR 范围内的相关性。
患者/方法:一项前瞻性研究纳入了 INR 水平不同的华法林抗凝治疗患者。为研究对象进行 CWA 和 CAT 检测。
纳入 54 例样本,INR 范围为 1.33-6.89,平均为 4.31±1.13。对于 CAT 参数,评估了内源性凝血酶潜能(ETP)和最大凝血酶。分别评估了未调整和调整(根据最终平台透射率调整)基于 aPTT 的 CWA 的 min1(最大速度)、min2(最大加速度)和 max2(最大减速度)参数。最大凝血酶与所有 CWA 参数均呈显著相关(min1:r=0.435,<0.001;min2:r=0.485,<0.001;max2:r=0.578,<0.001;调整 min1:r=0.734,<0.001,调整 min2:r=0.693,<0.001;调整 max2:r=0.751,<0.001)。ETP 与除未调整 min1 以外的所有 CWA 参数均显著相关(min1:r=0.235,=0.087;min2:r=0.326,=0.016;max2:r=0.437,<0.001;调整 min1:r=0.610,<0.001,调整 min2:r=0.563,<0.001;调整 max2:r=0.642,<0.001)。
我们在 CAT 和 CWA 参数之间显示了适度的相关性。调整后的 CWA 改善了这种相关性。这些发现为 CWA 及其在评估整体止血功能中的作用提供了更多的理解。