Suppr超能文献

X 连锁性视网膜劈裂的对比敏感度和等效内在噪声。

Contrast Sensitivity and Equivalent Intrinsic Noise in X-Linked Retinoschisis.

机构信息

Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Chicago, IL, USA.

Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA.

出版信息

Transl Vis Sci Technol. 2022 Mar 2;11(3):7. doi: 10.1167/tvst.11.3.7.

Abstract

PURPOSE

To define relationships among contrast sensitivity (CS), equivalent intrinsic noise (Neq; a measure of noise within the visual pathway), and retinal thickness in X-linked retinoschisis (XLRS).

METHODS

Nine XLRS and 10 visually-normal subjects participated. CS was measured in the presence and absence of luminance noise. These data were fit with a standard model to estimate Neq and sampling efficiency (an estimate of the ability to use stimulus information). Optical coherence tomography images were obtained to quantify outer nuclear layer (ONL+) and outer segment (OS+) thickness. A linear structure-function model was used to describe the relationship between CS and the product of ONL+ and OS+ thickness.

RESULTS

CS in the absence of noise (CS0) for the XLRS subjects ranged from normal to as much as 1.5× below the lower limit of normal. Four of the nine subjects with XLRS had abnormally high Neq, whereas two others had sampling efficiency that was borderline abnormal. Log CS0 for the subjects with XLRS was correlated significantly with log Neq (r = -0.78, P = 0.01), but not with log efficiency (r = 0.19, P = 0.63). CS0 and Neq, but not efficiency, conformed to the linear ONL+ × OS+ structure-function model.

CONCLUSIONS

The XLRS subjects in this study who had elevated internal noise had abnormally low CS; both internal noise and CS fell within the predicted limits of a structure-function model.

TRANSLATIONAL RELEVANCE

Internal noise measurements can provide insight into a source of CS loss in some individuals with XLRS.

摘要

目的

定义在 X 连锁性视网膜劈裂症(XLRS)中对比敏感度(CS)、等效固有噪声(Neq;视觉通路内噪声的一种衡量标准)和视网膜厚度之间的关系。

方法

9 名 XLRS 患者和 10 名视力正常的受试者参与了这项研究。在存在和不存在亮度噪声的情况下测量 CS。这些数据通过标准模型进行拟合,以估计 Neq 和采样效率(估计使用刺激信息的能力)。获得光学相干断层扫描图像以量化外核层(ONL+)和外节(OS+)厚度。使用线性结构-功能模型来描述 CS 与 ONL+和 OS+厚度乘积之间的关系。

结果

XLRS 受试者在无噪声(CS0)情况下的 CS 范围从正常到正常的 1.5 倍以下。9 名 XLRS 受试者中有 4 名的 Neq 异常升高,而另外 2 名的采样效率则处于临界异常状态。XLRS 受试者的对数 CS0 与对数 Neq 呈显著相关(r=-0.78,P=0.01),但与对数效率无关(r=0.19,P=0.63)。CS0 和 Neq,但不是效率,符合线性 ONL+×OS+结构-功能模型。

结论

本研究中,具有较高内噪声的 XLRS 受试者 CS 异常降低;内噪声和 CS 均在结构-功能模型的预测范围内。

翻译

张雨濛

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6013/8914567/6cc2bdeda220/tvst-11-3-7-f001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验