• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Comprehensive design analysis and verification of space-based short-wave infrared coded spectrometer via curved prism dispersion.

作者信息

Jia Xin-Yin, Li Xi-Jie, Hu Bing-Liang, Li Li-Bo, Wang Fei-Cheng, Zhang Zhao-Hui, Yang Ying, Ke Shan-Liang, Zou Chun-Bo, Liu Jia, Li Si-Yuan

出版信息

Appl Opt. 2022 Mar 10;61(8):2125-2139. doi: 10.1364/AO.449320.

DOI:10.1364/AO.449320
PMID:35297906
Abstract

The spaceborne dispersive spectrometer is widely used in environmental, resource, and ocean observations. The coded spectrometer has higher energy advantages than the dispersion spectrometer, so it has great application prospects. In the current study, we developed an off-axis short-wave infrared coded optical system (SICOS) based on curved prism dispersion, and we further explored the design and optimization of the SICOS structure. Finite element analyses of a space-based short-wave infrared coded spectrometer based on curved prism dispersion (SSICS-CPD), including static simulation, modal analysis, sinusoidal vibration mechanical analysis, and random vibration mechanical analysis, were carried out. Simulation results showed that the SICOS support structure had excellent mechanical and thermal stability. As off-axis optical systems cannot meet the requirements of optical position accuracy through centering processing, a point source microscope and three-coordinate measuring machines were employed to complete the high-precision and rapid assembly of the SSICS-CPD. In addition, verification tests of surface shape error, stress relief, random vibration, and optical design parameters were carried out to validate the high stability and imaging performance of the SSICS-CPD. Results showed that the average modulation transfer function in the full field was 0.43 at 16.67 lp/mm, the spectral smile was <0.2 pixels, and the spectral keystone was <0.1 pixels. The design, analysis, assembly, and verification of the SSICS-CPD provide a useful reference for the development of other spaceborne prism dispersion spectrometers.

摘要

相似文献

1
Comprehensive design analysis and verification of space-based short-wave infrared coded spectrometer via curved prism dispersion.
Appl Opt. 2022 Mar 10;61(8):2125-2139. doi: 10.1364/AO.449320.
2
Optical design of a short-wave infrared prism-grating imaging spectrometer.短波红外棱镜-光栅成像光谱仪的光学设计
Appl Opt. 2018 Dec 1;57(34):F8-F14. doi: 10.1364/AO.57.0000F8.
3
A design method for direct vision coaxial linear dispersion spectrometers.直视同轴线性色散光谱仪的一种设计方法。
Opt Express. 2022 Oct 10;30(21):38266-38283. doi: 10.1364/OE.465523.
4
[A wide-field push-broom hyperspectral imager based on curved prism].基于曲面棱镜的宽场推扫式高光谱成像仪
Guang Pu Xue Yu Guang Pu Fen Xi. 2012 Jun;32(6):1708-11.
5
Compact Shortwave Infrared Imaging Spectrometer Based on a Catadioptric Prism.基于折反射棱镜的紧凑型短波红外成像光谱仪。
Sensors (Basel). 2022 Jun 18;22(12):4611. doi: 10.3390/s22124611.
6
Design of a compact hyperspectral imaging spectrometer with a freeform surface based on anastigmatism.基于消像散的自由曲面紧凑型高光谱成像光谱仪设计
Appl Opt. 2020 Feb 20;59(6):1715-1725. doi: 10.1364/AO.379390.
7
Analytical design of a cemented-curved-prism based integral field spectrometer (CIFS) with high numerical aperture and high resolution.基于胶合弯棱镜的高数值孔径高分辨率积分场光谱仪(CIFS)的解析设计
Opt Express. 2022 Dec 19;30(26):48075-48090. doi: 10.1364/OE.477973.
8
Design analysis and test verification of a rigid-flexible, dual-mode coupling support structure for space-based rectangular curved prisms.用于天基矩形曲棱镜的刚柔双模式耦合支撑结构的设计分析与测试验证
Appl Opt. 2021 Sep 1;60(25):7563-7573. doi: 10.1364/AO.431394.
9
Design of short wave infrared imaging spectrometer system based on CDP.
Opt Express. 2015 Nov 16;23(23):29758-63. doi: 10.1364/OE.23.029758.
10
[Spectral scanning measurement of high-precision solar irradiance-meter].
Guang Pu Xue Yu Guang Pu Fen Xi. 2014 Mar;34(3):609-13.