Fritzler M J, Wall W, Gohill J, Kinsella T D, Humbel R L
Diagn Immunol. 1986;4(4):217-21.
An indirect immunoenzyme (IIE) kit to detect autoantibodies in the sera of patients with systemic rheumatic diseases has been evaluated and compared to a conventional indirect immunofluorescence (IIF) assay. Both IIF and IIE were performed on a human epithelial cell line (HEp-2) using sera categorized on the basis of their autoantibody specificity. The correlation coefficient between the two assays was greater than 0.77 for all autoantibodies except antimitochondrial antibodies, which had higher end-point titers with the IIE kit. The inter- and intratest variability of IIE and IIF was comparable, differing by no more than one tube dilution. The IIE test had less background staining, allowing for better resolution and easier interpretation of staining patterns. IIE assay in the form of a commercially available kit is a reliable alternative to IIF.
一种用于检测系统性风湿疾病患者血清中自身抗体的间接免疫酶(IIE)试剂盒已得到评估,并与传统的间接免疫荧光(IIF)检测方法进行了比较。IIF和IIE均使用基于自身抗体特异性分类的血清,在人上皮细胞系(HEp-2)上进行检测。除抗线粒体抗体外,两种检测方法之间的相关系数对于所有自身抗体均大于0.77,而抗线粒体抗体在IIE试剂盒中的终点滴度更高。IIE和IIF的批间和批内变异性相当,差异不超过一个试管稀释度。IIE检测的背景染色较少,能够更好地分辨并更易于解读染色模式。以市售试剂盒形式存在的IIE检测是IIF的可靠替代方法。