Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, University of Birmingham, UK.
Department of Rehabilitation and Prevention Engineering, Institute of Applied Medical Engineering, RWTH Aachen University, Aachen, Germany.
J Electromyogr Kinesiol. 2022 Jun;64:102656. doi: 10.1016/j.jelekin.2022.102656. Epub 2022 Mar 16.
High-density surface electromyography (HDsEMG) can be used to measure the spatial distribution of electrical muscle activity over the skin. As this distribution is associated with the generation and propagation of muscle fiber action potentials, HDsEMG is processed to extract information on regional muscle activation, muscle fiber characteristics and behaviour of individual motor units. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of HDsEMG in experimental studies. For each application, recommendations are included regarding electrode montage, electrode type and configuration, electrode location and orientation, data analysis, and interpretation. Cautions and reporting standards are also included. The steps of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers when collecting, reporting, and interpreting HDsEMG data. It is hoped that this document will be used to generate new empirical evidence to improve how HDsEMG is used in research and in clinical applications.
高密度表面肌电图(HDsEMG)可用于测量皮肤表面的电肌肉活动的空间分布。由于这种分布与肌肉纤维动作电位的产生和传播有关,因此对 HDsEMG 进行处理以提取有关区域肌肉激活、肌肉纤维特征和单个运动单位行为的信息。该矩阵由肌电图实验设计共识(CEDE)项目制定,总结了在实验研究中使用 HDsEMG 的建议。对于每种应用,都包括有关电极布置、电极类型和配置、电极位置和方向、数据分析和解释的建议。还包括注意事项和报告标准。达成共识的 Delphi 过程的步骤包含在附录中。该矩阵旨在帮助研究人员在收集、报告和解释 HDsEMG 数据时使用。希望本文件将用于生成新的经验证据,以改善 HDsEMG 在研究和临床应用中的使用方式。