Suppr超能文献

双对比 micro-CT 可用于体外检测软骨损伤和评估组织状态。

Dual-contrast micro-CT enables cartilage lesion detection and tissue condition evaluation ex vivo.

机构信息

Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.

Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.

出版信息

Equine Vet J. 2023 Mar;55(2):315-324. doi: 10.1111/evj.13573. Epub 2022 Mar 30.

Abstract

BACKGROUND

Post-traumatic osteoarthritis is a frequent joint disease in the horse. Currently, equine medicine lacks effective methods to diagnose the severity of chondral defects after an injury.

OBJECTIVES

To investigate the capability of dual-contrast-enhanced computed tomography (dual-CECT) for detection of chondral lesions and evaluation of the severity of articular cartilage degeneration in the equine carpus ex vivo.

STUDY DESIGN

Pre-clinical experimental study.

METHODS

In nine Shetland ponies, blunt and sharp grooves were randomly created (in vivo) in the cartilage of radiocarpal and middle carpal joints. The contralateral joint served as control. The ponies were subjected to an 8-week exercise protocol and euthanised 39 weeks after surgery. CECT scanning (ex vivo) of the joints was performed using a micro-CT scanner 1 hour after an intra-articular injection of a dual-contrast agent. The dual-contrast agent consisted of ioxaglate (negatively charged, q = -1) and bismuth nanoparticles (BiNPs, q = 0, diameter ≈ 0.2 µm). CECT results were compared to histological cartilage proteoglycan content maps acquired using digital densitometry.

RESULTS

BiNPs enabled prolonged visual detection of both groove types as they are too large to diffuse into the cartilage. Furthermore, proportional ioxaglate diffusion inside the tissue allowed differentiation between the lesion and ungrooved articular cartilage (3 mm from the lesion and contralateral joint). The mean ioxaglate partition in the lesion was 19 percentage points higher (P < 0.001) when compared with the contralateral joint. The digital densitometry and the dual-contrast CECT findings showed good subjective visual agreement.

MAIN LIMITATIONS

Ex vivo study protocol and a low number of investigated joints.

CONCLUSIONS

The dual-CECT methodology, used in this study for the first time to image whole equine joints, is capable of effective lesion detection and simultaneous evaluation of the condition of the articular cartilage.

摘要

背景

创伤后骨关节炎是马的一种常见关节疾病。目前,马医学缺乏有效方法来诊断损伤后软骨缺陷的严重程度。

目的

研究双对比增强计算机断层扫描(dual-CECT)检测马腕关节软骨病变和评估关节软骨退变严重程度的能力。

研究设计

临床前实验研究。

方法

在 9 匹设得兰矮马中,随机在腕关节和中腕关节的软骨中造成钝性和锐性沟槽(体内)。对侧关节作为对照。这些马接受了 8 周的运动方案,并在手术后 39 周被安乐死。在关节内注射双对比剂后 1 小时,使用微 CT 扫描仪对关节进行 CECT 扫描(离体)。双对比剂由碘海醇(带负电荷,q=-1)和铋纳米颗粒(BiNPs,q=0,直径≈0.2μm)组成。CECT 结果与使用数字密度测定法获得的组织软骨蛋白聚糖含量图谱进行比较。

结果

BiNPs 太大而无法扩散到软骨中,因此可以长时间观察到两种类型的沟槽,从而使它们能够被长时间观察到。此外,组织内碘海醇的比例扩散允许区分病变和未开槽的关节软骨(距病变 3 毫米处和对侧关节)。与对侧关节相比,病变部位的碘海醇分区平均高 19 个百分点(P<0.001)。数字密度测定法和双对比 CECT 结果显示出良好的主观视觉一致性。

主要局限性

离体研究方案和被检查关节数量较少。

结论

本研究首次将双 CECT 方法用于成像整个马关节,该方法能够有效检测病变,并同时评估关节软骨的状况。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4c6d/10084070/d42b1ed6dca5/EVJ-55-315-g005.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验