Three south-London hospital trusts undertook a feasibility study, comparing data from 93 patients who received the 14-day adhesive ambulatory electrocardiography (ECG) patch Zio XT with retrospective data from 125 patients referred for 24-hour Holter for cryptogenic stroke and transient ischaemic attack following negative 12-lead ECG. As the ECG patch was fitted the same day as the clinical decision for ambulatory ECG monitoring was made, median time to the patient having the monitor fitted was significantly reduced in all three hospital trusts compared with 24-hour Holter being ordered and fitted. Hospital visits reduced by a median of two for patients receiving Zio XT. This project supports that it is feasible to use a patch as part of routine clinical care with a positive impact on care pathways.

摘要

伦敦南部的三家医院信托机构进行了一项可行性研究,将93名使用为期14天的可粘贴式动态心电图(ECG)贴片Zio XT的患者数据,与125名因12导联心电图呈阴性而被转诊进行24小时动态心电图监测以诊断隐匿性中风和短暂性脑缺血发作的患者的回顾性数据进行了比较。由于心电图贴片是在做出动态心电图监测临床决定的同一天安装的,与订购和安装24小时动态心电图相比,所有三家医院信托机构中患者安装监测器的中位时间都显著缩短。接受Zio XT的患者门诊次数中位数减少了两次。该项目支持将贴片作为常规临床护理的一部分是可行的,对护理路径有积极影响。

相似文献

2
Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring.
Am J Med. 2014 Jan;127(1):95.e11-7. doi: 10.1016/j.amjmed.2013.10.003. Epub 2013 Oct 15.
3
Comparing 14-day adhesive patch with 24-h Holter monitoring.
Future Cardiol. 2014 May;10(3):319-22. doi: 10.2217/fca.14.24.
4
Ambulatory Arrhythmia Detection with ZIO® XT Patch in Pediatric Patients: A Comparison of Devices.
Pediatr Cardiol. 2019 Jun;40(5):921-924. doi: 10.1007/s00246-019-02089-0. Epub 2019 Apr 1.
6
Diagnostic Yield, Outcomes, and Resource Utilization With Different Ambulatory Electrocardiographic Monitoring Strategies.
Am J Cardiol. 2022 Mar 1;166:38-44. doi: 10.1016/j.amjcard.2021.11.027. Epub 2021 Dec 23.
10
Use of a noninvasive continuous monitoring device in the management of atrial fibrillation: a pilot study.
Pacing Clin Electrophysiol. 2013 Mar;36(3):328-33. doi: 10.1111/pace.12053. Epub 2012 Dec 13.

引用本文的文献

1
Wearable Devices for Arrhythmia Detection: Advancements and Clinical Implications.
Sensors (Basel). 2025 Apr 30;25(9):2848. doi: 10.3390/s25092848.
2
Use of wearable technology in cardiac monitoring after cryptogenic stroke or embolic stroke of undetermined source: a systematic review.
Singapore Med J. 2024 Jul 1;65(7):370-379. doi: 10.4103/singaporemedj.SMJ-2022-143. Epub 2024 Mar 6.

本文引用的文献

2
Embolic strokes of undetermined source: the case for a new clinical construct.
Lancet Neurol. 2014 Apr;13(4):429-38. doi: 10.1016/S1474-4422(13)70310-7.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验